ODSHR Outdoor Woodburning Fireplace
Accessories
The following accessories for this appliance are available from your local CFM Corporation products distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd., Mississauga, Ontario, Canada L5N 8A3, Attn: Technical Services.
CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper- ated only with CFM Corporation approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the CFM Corporation warranty. In addition, such action may void the coverage provided by the owner’s insurance.
Accessory | Description | Model No. | ||
|
|
|
| |
Glass Enclosure Kit | Designed to enclose the fireplace opening | 42SHGDKDP/BB/BK/SS/S | ||
| with glass doors allowing the fire to remain | |||
|
|
| ||
| visible. Available in Polished, Brushed |
|
| |
| Brass, Black, Stainless Steel and Pewter |
|
| |
|
|
|
| |
Outside Air Kit | Provides outside air for fuel conbustion |
| ||
|
| |||
| in the firebox. This accessory must be |
|
| |
| installed before fireplace is installed. |
|
| |
|
|
| ||
Hearth Extension | Located on the floor in front of fireplace | EH2416 | ||
|
| |||
| to protect the floor from heat, hot embers, |
|
| |
| ashes, etc. |
|
| |
|
|
|
| |
Hearth Patching Kit | Used to patch cracks in hearth. | HPC1 | ||
|
| |||
|
|
| ||
Wall Shield | Used to protect walls adjacent to the fire- | SP40 | ||
|
| |||
| place. |
|
| |
|
|
|
| |
Firestop | Required at each floor level and attic on | FS2A (straight flue) | ||
FS6A (30° inclined flue) | ||||
| ||||
|
|
| ||
|
|
|
| |
Chimney Support | Used to support the chimney at each 30 | 11CS (11" flue) | ||
|
| |||
| feet of vertical height above the hearth and |
|
| |
| at every 6 feet of inclined chimney run. |
|
| |
| Each support adds 2¹⁄₂" to chimney length. |
|
| |
|
|
|
| |
Contemporary Flashing | Required for contemporary top termination |
| ||
(0 to 6/12 pitch) | ||||
| on the roof to prevent rain entry. | |||
|
| |||
|
|
| ||
|
| (6/12 to 12/12 pitch) | ||
|
|
|
| |
Contemporary Chase Top Termina- | Used to terminate chimney at the top of a | SLTCF11 | ||
tion | chase. Adapter kit is included, flashing is | |||
|
| |||
| not included. |
|
| |
|
|
|
| |
Contemporary Round Top Termina- | For use with Type "11CF" Chimney Sys- | RLTCF11 | ||
tion | tems. | |||
|
| |||
| Used to terminate chimney on the roof. |
|
| |
| Flashing not included. |
|
| |
|
|
|
|
20 | 20002264 |