Direct Access Parameter Information
The G7 ASD has the ability to allow the user direct access to the motor control functions. The functions listed below have an associated Parameter Number which accesses its setting. There are two ways in which the
The Program mode allows the user to develop an
Note: The setup procedures included within this section may require a Reset before performing the procedure.
Direct Access Parameters/Numbers
Automatic Accel/Decel #1
Program ⇒ Fundamental Parameters ⇒ Accel/Decel #1 Settings
This parameter Enables/Disables the ability of the ASD to adjust the acceleration and deceleration rates in accordance with the applied load automatically.
The adjusted acceleration and deceleration times range from 12.5% to 800% of the programmed values for Acceleration Time #1 (F009) and Deceleration Time #1 (F010).
Settings:
Disabled
Enabled (box checked)
Direct Access Number — F000
Parameter Type — Check Box
Factory Default — Disabled
Changeable During Run — No
Note: The motor and the load must be connected prior to selecting Automatic Accel/Decel.
Command Mode Selection
Program ⇒ Fundamental Parameters ⇒ Standard Mode Selection ⇒
Command Mode
The Command Mode Selection establishes the source of the command input for the ASD. Command inputs include Run, Stop, Forward, etc. The Override feature may supersede the Command Mode Selection setting (see Command Mode and Frequency Mode Control on pg. 31).
Settings:
Use Control Terminal Strip
Use LED Keypad Option
Use Common Serial (TTL)
Use RS232/RS485
Use Communication Card
Direct Access Number — F003
Parameter Type — Selection List
Factory Default — Use Control
Terminal Strip
Changeable During Run — No