Panel Menu
The Panel menu may be accessed in either of two ways: while operating using the LED Keypad Option the Panel menu may be accessed via F008 or if operating in the Local mode using the LCD EOI, press ESC from the Frequency Command screen.
The control settings of the Panel menu are effective for LED keypad control only if accessed via Direct Access method F008 and are effective for the LCD EOI control only if accessed via the Frequency Command screen. Changes made to either of the Panel menus are not carried over to the other Panel menu.
Using either method provides quick access to the following Panel menu parameters:
Direction — Forward or Reverse (see F008 for further information on this setting).
Stop Pattern — The Decel Stop or Coast Stop settings determines the method used to stop the motor when using the StopReset key of the EOI. The Decel Stop setting enables the Dynamic Braking system setup at F304 or the DC Injection Braking system setup at F250, F251, and F252. The Coast Stop setting allows the motor to stop at the rate allowed by the inertia of the load.
Note: The Stop Pattern setting has no effect on the Emergency Off settings of F603.
V/f Group — 1 of 4 V/f profiles may be selected and run. Each V/f profile is comprised of 4 user settings: Base Frequency, Base Frequency Voltage, Manual Torque Boost, and Electronic Thermal Protection. Expanded descriptions of these parameters may be found in the section titled Direct Access Parameter Information on pg. 59.
Accel/Decel Group — 1 of 4 Accel/Decel profiles may be selected and run. Each of the Accel/Decel profiles is comprised of 3 user settings: Acceleration, Deceleration, and Pattern. Expanded descriptions of these parameters may be found in the section titled Direct Access Parameter Information on pg. 59 (or see F009).
Feedback in Panel Mode — This feature enables or disables the PID feedback function.
Torque Limit Group — This parameter is used to select 1 of 4 preset positive torque limits to apply to the active motor (of a multiple motor configuration). The settings of profiles 1 – 4 may be setup at F441, F444, F446, and F448, respectively.
44 | G7 ASD Operation Manual |