F337 | F341 |
Heavy-Load Torque During Forward Deceleration
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒
Deceleration
During forward deceleration, this parameter establishes the threshold torque level that is used to determine if the
If the
Direct Access Number — F337
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Switching Load Torque During Reverse-Run
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒ Switching Load Torque During Reverse
Run
While running in reverse, this parameter establishes the threshold torque level that is used to determine if the
If the
Direct Access Number — F338
Parameter Type — Numerical
Factory Default — 50
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Reverse Acceleration
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒
Acceleration
During reverse acceleration, this parameter establishes the threshold torque level that is used to determine if the
If the
Direct Access Number — F339
Parameter Type — Numerical
Factory Default — 150
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Reverse Deceleration
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒
Deceleration
During reverse deceleration, this parameter establishes the threshold torque level that is used to determine if the
If the
Direct Access Number — F340
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Frequency for Automatic High-Speed Operation at Light- Load
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒ Frequency for Automatic
Operation at Light-Load
This parameter establishes the speed that the ASD will ramp to when operating in the
Direct Access Number — F341
Parameter Type — Numerical
Factory Default — 80
Changeable During Run — Yes
Minimum — 0.00
Maximum — 80.00
Units — %
G7 ASD Operation Manual | 119 |