F337

F341

Heavy-Load Torque During Forward Deceleration

Program Special Control Parameters Crane/Hoist Settings Express Speed Settings Heavy-Load Torque During Forward

Deceleration

During forward deceleration, this parameter establishes the threshold torque level that is used to determine if the Light-LoadHigh-Speed(F331) operation may engage or remain engaged if active.

If the Light-LoadHigh-Speedoperation is terminated normal operation resumes.

Direct Access Number — F337

Parameter Type — Numerical

Factory Default — 100

Changeable During Run — Yes

Minimum — 0

Maximum — 250

Units — %

Switching Load Torque During Reverse-Run

Program Special Control Parameters Crane/Hoist Settings Express Speed Settings Switching Load Torque During Reverse

Run

While running in reverse, this parameter establishes the threshold torque level that is used to determine if the Light-LoadHigh-Speed(F331) operation may engage or remain engaged if active.

If the Light-LoadHigh-Speedoperation is terminated normal operation resumes.

Direct Access Number — F338

Parameter Type — Numerical

Factory Default — 50

Changeable During Run — Yes

Minimum — 0

Maximum — 250

Units — %

Heavy-Load Torque During Reverse Acceleration

Program Special Control Parameters Crane/Hoist Settings Express Speed Settings Heavy-Load Torque During Reverse

Acceleration

During reverse acceleration, this parameter establishes the threshold torque level that is used to determine if the Light-LoadHigh-Speed(F331) operation may engage or remain engaged if active.

If the Light-LoadHigh-Speedoperation is terminated normal operation resumes.

Direct Access Number — F339

Parameter Type — Numerical

Factory Default — 150

Changeable During Run — Yes

Minimum — 0

Maximum — 250

Units — %

Heavy-Load Torque During Reverse Deceleration

Program Special Control Parameters Crane/Hoist Settings Express Speed Settings Heavy-Load Torque During Reverse

Deceleration

During reverse deceleration, this parameter establishes the threshold torque level that is used to determine if the Light-LoadHigh-Speed(F331) operation may engage or remain engaged if active.

If the Light-LoadHigh-Speedoperation is terminated normal operation resumes.

Direct Access Number — F340

Parameter Type — Numerical

Factory Default — 100

Changeable During Run — Yes

Minimum — 0

Maximum — 250

Units — %

Frequency for Automatic High-Speed Operation at Light- Load

Program Special Control Parameters Crane/Hoist Settings Express Speed Settings Frequency for Automatic High-Speed

Operation at Light-Load

This parameter establishes the speed that the ASD will ramp to when operating in the Light-LoadHigh-Speedmode.

Direct Access Number — F341

Parameter Type — Numerical

Factory Default — 80

Changeable During Run — Yes

Minimum — 0.00

Maximum — 80.00

Units — %