F503

 

F507

 

 

 

 

 

Accel/Decel Pattern #2

Direct Access Number —

F503

 

Program Special Control Parameters 1 – #4 Settings

Parameter Type — Selection List

 

This parameter enables a user-selected preprogrammed output profile that

Factory Default — Linear

 

 

Changeable During Run — Yes

 

controls the acceleration and deceleration pattern for the #2 Accel/Decel

 

 

 

 

parameter.

 

 

 

Settings:

 

 

 

Linear

 

 

 

S-Pattern 1

 

 

 

S-Pattern 2

 

 

 

 

 

 

 

Acc/Dec Group

Direct Access Number —

F504

 

No path available (Direct Access Only)

Parameter Type — Selection List

 

While operating using the LED Keypad Option this parameter selects the

Factory Default — 1

 

 

Changeable During Run — Yes

 

accel/decel profile to be used during a multiple-accel/decel profile

 

 

 

 

configuration. The accel/decel setting for selections 1 – 4 may be found at

 

 

 

F009, F500, F510, and F514, respectively.

 

 

 

Settings:

 

 

 

Group 1

 

 

 

Group 2

 

 

 

Group 3

 

 

 

Group 4

 

 

 

Note: If using the LCD EOI, press ESC from the Frequency

 

 

 

Command screen to access this parameter.

 

 

 

 

 

 

 

Acc/Dec Switching Frequency #1

Direct Access Number —

F505

 

Program Special Control Parameters Accel/Decel Special

Parameter Type — Numerical

 

This parameter sets the frequency at which the acceleration control is switched

Factory Default — 0.00

 

 

Changeable During Run — Yes

 

from the Accel #1 profile to the Accel #2 profile during a multiple-acceleration

 

 

 

 

profile configuration.

Minimum — 0.00

 

 

 

Maximum — Max. Freq. (F011)

 

 

Units — Hz

 

 

 

 

 

 

S-Pattern Lower Limit Adjustment

Direct Access Number —

F506

 

Program Special Control Parameters Accel/Decel Special

Parameter Type — Numerical

 

Sets the lower limit of S-pattern 1 and 2.

Factory Default — 25.00

 

 

Changeable During Run — Yes

 

 

 

 

Minimum — 0.00

 

 

 

Maximum — 50.00

 

 

 

Units — %

 

 

 

 

 

 

S-Pattern Upper Limit Adjustment

Direct Access Number —

F507

 

Program Special Control Parameters Accel/Decel Special

Parameter Type — Numerical

 

 

Factory Default — 25.00

 

Sets the upper limit frequency of S-pattern 1 and 2.

Changeable During Run — Yes Minimum — 0.00 Maximum — 50.00

Units — %

142