F212

F215

RR Speed Reference Setpoint #2 (%)

Program Frequency Setting Parameters Speed Reference Setpoints RR

This parameter is used to set the gain and bias of the RR input terminal when this terminal is used as the control input while operating in the Speed Control or the Torque Control mode.

See F210 for further information on this setting.

This parameter sets the RR input level that represents RR Reference Setpoint #2 (frequency) (torque or frequency). This value is entered as 0 – 100% of the 0 – 10 VDC RR input signal range.

Direct Access Number — F212

Parameter Type — Numerical

Factory Default — 100.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — 100.0

Units — %

RR Speed Reference Setpoint #2 (frequency)

Program Frequency Setting Parameters Speed Reference Setpoints RR

This parameter is used to set the gain and bias of the RR input terminal when this terminal is used as the control input while operating in the Speed Control mode.

See F210 for further information on this setting.

This parameter sets RR Speed Reference Setpoint #2 (frequency) and is the frequency that is associated with the setting of F212.

Direct Access Number — F213

Parameter Type — Numerical

Factory Default — 80.0

Changeable During Run — Yes

Minimum — 0.0

Maximum — 100.0

Units — Hz

RR Torque Reference Setpoint #1 (%)

Direct Access Number —

F214

Program Torque Setting Parameters Setpoints RR

Parameter Type — Numerical

This parameter is used to set the gain and bias of the RR input terminal when

Factory Default — 0.0

 

Changeable During Run — Yes

this terminal is used as the control input while operating in the Torque Control

 

 

mode.

Minimum — 0.0

 

This is accomplished by establishing an associated V/f output pattern for a given

Maximum — 250.0

 

RR input level and motor load.

Units — %

 

 

 

See F210 for further information on this setting.

 

 

This parameter sets RR Torque Reference Setpoint #1 and is the output torque

 

 

value that is associated with setting of F210. This value is entered as 0 – 250%

 

 

of the rated torque.

 

 

 

 

 

RR Torque Reference Setpoint #2 (%)

Direct Access Number —

F215

Program Torque Setting Parameters Setpoints RR

Parameter Type — Numerical

This parameter is used to set the gain and bias of the RR input terminal when

Factory Default — 100.0

 

Changeable During Run — Yes

this terminal is used as the control input while operating in the Torque Control

 

 

mode.

Minimum — 0.0

 

This is accomplished by establishing an associated V/f output pattern for a given

Maximum — 250.0

 

RR input level and motor load.

Units — %

 

 

 

See F210 for further information on this setting.

This parameter sets RR Torque Reference Setpoint #2 and is the output torque value that is associated with setting of F212. This value is entered as 0 – 250% of the rated torque.

96

G7 ASD Operation Manual

Page 102
Image 102
Toshiba G7 RR Speed Reference Setpoint #2 %, RR Speed Reference Setpoint #2 frequency, RR Torque Reference Setpoint #1 %