F212 | F215 |
RR Speed Reference Setpoint #2 (%)
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference Setpoints ⇒ RR
This parameter is used to set the gain and bias of the RR input terminal when this terminal is used as the control input while operating in the Speed Control or the Torque Control mode.
See F210 for further information on this setting.
This parameter sets the RR input level that represents RR Reference Setpoint #2 (frequency) (torque or frequency). This value is entered as 0 – 100% of the 0 – 10 VDC RR input signal range.
Direct Access Number — F212
Parameter Type — Numerical
Factory Default — 100.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 100.0
Units — %
RR Speed Reference Setpoint #2 (frequency)
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference Setpoints ⇒ RR
This parameter is used to set the gain and bias of the RR input terminal when this terminal is used as the control input while operating in the Speed Control mode.
See F210 for further information on this setting.
This parameter sets RR Speed Reference Setpoint #2 (frequency) and is the frequency that is associated with the setting of F212.
Direct Access Number — F213
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 100.0
Units — Hz
RR Torque Reference Setpoint #1 (%) | Direct Access Number — | F214 | |
Program ⇒ Torque Setting Parameters ⇒ Setpoints ⇒ RR | Parameter Type — Numerical | ||
This parameter is used to set the gain and bias of the RR input terminal when | Factory Default — 0.0 |
| |
Changeable During Run — Yes | |||
this terminal is used as the control input while operating in the Torque Control | |||
|
| ||
mode. | Minimum — 0.0 |
| |
This is accomplished by establishing an associated V/f output pattern for a given | Maximum — 250.0 |
| |
RR input level and motor load. | Units — % |
| |
|
| ||
See F210 for further information on this setting. |
|
| |
This parameter sets RR Torque Reference Setpoint #1 and is the output torque |
|
| |
value that is associated with setting of F210. This value is entered as 0 – 250% |
|
| |
of the rated torque. |
|
| |
|
|
| |
RR Torque Reference Setpoint #2 (%) | Direct Access Number — | F215 | |
Program ⇒ Torque Setting Parameters ⇒ Setpoints ⇒ RR | Parameter Type — Numerical | ||
This parameter is used to set the gain and bias of the RR input terminal when | Factory Default — 100.0 |
| |
Changeable During Run — Yes | |||
this terminal is used as the control input while operating in the Torque Control | |||
|
| ||
mode. | Minimum — 0.0 |
| |
This is accomplished by establishing an associated V/f output pattern for a given | Maximum — 250.0 |
| |
RR input level and motor load. | Units — % |
| |
|
|
See F210 for further information on this setting.
This parameter sets RR Torque Reference Setpoint #2 and is the output torque value that is associated with setting of F212. This value is entered as 0 – 250% of the rated torque.
96 | G7 ASD Operation Manual |