G7 ASD Operation Manual 161
Acc/Dec Base Frequency Adjustment
Program Terminal Selection Parameters Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Base Frequency. When enabled, either VI/II or RR may be
used as an input source for the modification of the Base Frequency setting.
Settings:
Disabled
VI/II
RR
Direct Access Number — F650
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Upper Limit Frequency Adjustment
Program Terminal Selection Parameters Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Upper Limit. When enabled, either VI/II or RR may be used
as an input source for the modification of the Upper Limit setting.
Settings:
Disabled
VI/II
RR
Direct Access Number — F651
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Acceleration Time Adjustment
Program Terminal Selection Parameters Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Acceleration T ime. Selecting either VI/II or RR en ables this
feature. The selec ted input is used as a multiplier of the pr ogrammed
Acceleration Time setting. The multiplication factor may be from 1 to 10.
Note: An acceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads.
Settings:
Disabled
VI/II
RR
Direct Access Number — F652
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Deceleration Time Adjustment
Program Terminal Selection Parameters Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Deceleration T ime. Selecting either VI/II or RR en ables this
feature. The selected input is used as a modifier of the programmed
Deceleration Time setting.
Note: A deceleration time shorter than the load will allow m ay cause
nuisance tripping and mechanical stress to loads.
Settings:
Disabled
VI/II
RR
Direct Access Number — F653
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
F650 F653