G7 ASD Operation Manual 193
Current/Voltage Specifications
Table 15. 230 Volt NEMA Type-1/IP-20 Chassis standard ratings table.
Model
VT130G7U Rated
KVA Motor
HP/Kw
Input Voltage
3-Ph 50/60
± 2 Hz
Output Voltage
3-Ph Variable
Frequency
Output Current
100/110% Cont.
Overload
Current
150% for
60 Secs.
Overload
Current
150% for
120 Secs.
2010B 1.0 0.75/0.56
200 – 240 VAC
(±10%) In put Voltage Level
(Max.)
3.5/3.9 A 5.3 A
2015B 1.5 1.0/0.75 5.0/5.5 A 7.5 A
2025B 2.5 2.0/1.5 7.0/7.7 A 10.5 A
2035B 3.5 3.0/2.2 10.0/11.0 A 15.0 A
2055B 5.5 5.0/3.7 16.0/17.6 A 24.0 A
2080B 8.0 7.5/5.6 23.0/25.3 A 34.5 A
2110B 11 10/7.5 30.0/33.0 A 45.0 A
2160B 16 15/11.2 45.0/49.5 A 67.5 A
2220B 22 20/14.9 60.0/66.0 A 90.0 A
2270B 27 25/18.5 71.0/78.1 A 106.5 A
2330B 33 30/22.0 90.0/99.0 A 135.0 A
* 2400B 40 40/30 110/121.0 A 126.5 A
* 2500B 50 50/37 138/151.8 A 158.7 A
* 2600B 60 60/45 172/189.2 A 197.8 A
* 2750B 75 75/55 206/226.6 A 236.9 A
* 210KB 100 100/75 275/302.5 A 316.3 A
* 212KB 125 125/90 343/377.3 A 394.5 A
* 215KB 150 150/110 415/456.5 A 477.3 A
Note: *12-Pulse option available.
Table 16. 460 Volt NEMA Type-1/IP-20 Chassis standard ratings table.
Model
VT130G7U Rated
KVA Motor
HP/Kw
Input Voltage
3-Ph 50/60
± 2 Hz
Output Voltage
3-Ph Variable
Frequency
Output
Current 100/
110% Cont.
Overload
Current
130% for
120 Secs.
Overload
Current
150% for
60 Secs.
Overload
Current
150% for
120 Secs.
4015B 1.5 1.0/0.75
380 – 480 VAC
(±10%) Input Voltag e
Level (Max.)
2.7/3.0 A
N/A N/A
4.1 A
4025B 2.5 2.0/1.5 3.5/3.9 A 5.3 A
4035B 3.5 3.0/2.2 5.0/5.5 A 7.5 A
4055B 5.5 5.0/3.7 8.0/8.8 A 12.0 A
4080B 8.0 7.5/5.6 11.5/12.7 A 17.3 A
4110B 11.0 10.0/7.5 15. 0/16.5 A 22.5 A
4160B 16.0 15.0/11.2 23.0/25.3 A 34.5 A
4220B 22.0 20.0/14.9 30.0/33.0 A 45.0 A