F194

F199

Custom V/f Five-Point Setting #3 Frequency

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five Point Setting #3 Frequency sets the frequency to be associated with parameter F195 (Custom V/f Five Point Setting #3 Voltage).

See F190 for additional information on custom V/f curves.

Direct Access Number — F194

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 299

Units — Hz

Custom V/f Five-Point Setting #3 Voltage

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five-Point Setting #3 Voltage establishes the percentage of the output voltage that is to be associated with the frequency setting of F194 (Custom V/f Five Point Setting #3 Frequency).

See F190 for additional information on custom V/f curves.

Direct Access Number — F195

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 100.0

Units — %

Custom V/f Five-Point Setting #4 Frequency

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five Point Setting #4 Frequency sets the frequency to be associated with parameter F197 (Custom V/f Five Point Setting #4 Voltage).

See F190 for additional information on custom V/f curves.

Direct Access Number — F196

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 299

Units — Hz

Custom V/f Five-Point Setting #4 Voltage

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five-Point Setting #4 Voltage establishes the percentage of the output voltage that is to be associated with the frequency setting of F196 (Custom V/f Five Point Setting #4 Frequency).

See F190 for additional information on custom V/f curves.

Direct Access Number — F197

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 100.0

Units — %

Custom V/f Five-Point Setting #5 Frequency

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five Point Setting #5 Frequency sets the frequency to be associated with parameter F199 (Custom V/f Five Point Setting #5 Voltage).

See F190 for additional information on custom V/f curves.

Direct Access Number — F198

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 299

Units — Hz

Custom V/f Five-Point Setting #5 Voltage

Program Special Control Parameters V/f Five-Point Setting

The Custom V/f Five-Point Setting #5 Voltage establishes the percentage of the output voltage that is to be associated with the frequency setting of F198 (Custom V/f Five Point Setting #5 Frequency).

See F190 for additional information on custom V/f curves.

Direct Access Number — F199

Parameter Type — Numerical

Factory Default — 0.0

Changeable During Run — No

Minimum — 0.0

Maximum — 100.0

Units — %

90

G7 ASD Operation Manual

Page 96
Image 96