F364

F369

Upper Deviation Limits

Program Feedback Parameters Feedback Settings

This parameter determines the maximum amount that the feedback may increase the output signal.

Direct Access Number — F364

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 50.00

Units — %

Lower Deviation Limits

Program Feedback Parameters Feedback Settings

This parameter determines the maximum amount that the feedback may decrease the output signal.

Direct Access Number — F365

Parameter Type — Numerical

Factory Default — 50.00

Changeable During Run — Yes

Minimum — 0.00

Maximum — 50.00

Units — %

Feedback Settings Differential (D) Gain

Program Feedback Parameters Feedback Settings

This parameter determines the degree that the Differential function affects the output signal. The larger the value entered here, the more pronounced the affect of the differential function for a given feedback signal level.

Direct Access Number — F366

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — 0.0

Maximum — 2.55

Number of PG Input Pulses

Program Feedback Parameters PG Settings

This parameter is used to set the end-of-travel range when using an encoder on a motor-driven positioning system (e.g., hoist/crane, etc.).

Direct Access Number — F367

Parameter Type — Numerical

Factory Default — 500

Changeable During Run — No

Minimum — 1

Maximum — 9999

Units — Pulse Count

PG Input Phases

Direct Access Number —

F368

Program Feedback Parameters PG Settings

Parameter Type — Selection List

This parameter determines the type of information that is supplied by the phase

Factory Default — 2

 

Changeable During Run — No

encoder.

 

 

 

Minimum — 1

 

Settings:

Maximum — 2

 

 

 

1 — Speed

Units — Phase Count

 

2 — Speed and Direction

 

 

 

 

 

 

PG Disconnect Detection

Direct Access Number —

F369

Program Feedback Parameters PG Settings

Parameter Type — Selection List

 

Factory Default — Disabled

 

This parameter Enables/Disables the system’s monitoring of the PG connection

status when using encoders with line driver outputs.

Settings:

Disabled

Enabled

Changeable During Run — No