La Crosse Technology WS-9043U C.Resetting The Mimimum And Maximum Records, V.Moon Phase

Models: WS-9043U

1 14
Download 14 pages 50 Kb
Page 10
Image 10
C.RESETTING THE MIMIMUM AND MAXIMUM RECORDS

date of occurrence are displayed. The maximum record will display for 30 seconds before returning to the normal display mode.

8.Press and release the OUT/MIN button again (once while “MAX” dew point is still displayed, 8 times otherwise). “MIN” appears with the dew point, indicating that the minimum dew point and the time and date of occurrence are displayed. The minimum record will display for 30 seconds before returning to the normal display mode.

9.While “MIN” is still displayed, press and release the OUT/MIN button again to return to the current data display. While in the record display mode, pressing any key except SET key will also return the display back to the current readings.

C.RESETTING THE MIMIMUM AND MAXIMUM RECORDS

To reset the INDOOR records:

1.Press and release the IN/HR button to select the record you wish to reset, either MAX or MIN.

2.Press and hold the SET button for 5 seconds.

3.The record is now reset and will show the current time in the TIME LCD and current indoor temperature or humidity in the INDOOR LCD.

To reset the OUTDOOR records:

1.Press and release the OUT/MIN button to select the record you wish to reset, either MAX or MIN

2.Press and hold the SET button for 5 seconds.

3.The record is now reset and will show the current time in the TIME LCD and current outdoor temperature, humidity, heat index or dew point in the OUTDOOR LCD.

V.MOON PHASE

There are 12 moon phases shown on the indoor weather station. Thus, when the moon icon is all white, it is a full moon.

New Moon

Small Waxing Crescent

Large Waxing Crescent First Quarter

Small Waxing Gibbous Large Waxing Gibbous

Full Moon

Large Waning Gibbous

Small Waning Gibbous Last Quarter

Large Waning Crescent Small Waning Crescent

VI.

TIME ALARM

To set the time alarm:

1.Press and hold the ALM/+ button for 3 seconds.

2.The alarm time will begin to flash in the DATE LCD.

3.Press and release the IN/HR button to adjust the hour.

Note: When in the 12-hour mode and setting an alarm for a time between noon and midnight, “PM” will appear to the left of the alarm time in the DATE LCD.

4.Press and release the OUT/MIN button to adjust the minutes.

5.Press and release the SNOOZE/CH button to confirm the setting or wait for 15 seconds and the display will automatically return to the normal mode.

To activate the alarm:

1.Press and release the ALM/+ button to toggle between the alarm time and the day and date.

2.When the alarm time and alarm icon are showing in the DATE LCD the alarm is activated.

3.When the day and date are showing in the DATE LCD the alarm is deactivated.

To activate the snooze:

1.While the alarm is sounding press and release the SNOOZE/CH button.

2.The snooze will be activated and the alarm will come back on after the selected time period.

VII. ADDING REMOTE TEMPERATURE/HUMIDITY SENSORS (OPTIONAL)

The WS-9043U is able to receive signals from 3 different remote temperature/humidity sensors. The remote temperature/humidity sensor model(s) that you choose will come with their own set of instructions—follow these instructions for a complete guide to setting up. Following are some brief instructions for the basic set-up of remote temperature/humidity sensor units with the WS-9043U. These extra sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly. A TX4U will monitor temperature and humidity, a TX6U will

10

Page 10
Image 10
La Crosse Technology WS-9043U C.Resetting The Mimimum And Maximum Records, To reset the INDOOR records, V.Moon Phase