G7 ASD Operation Manual 165
Accel/Decel Special Display Resolution
Program Special Control Parameters Accel/Decel Special
This parameter sets the number of decimal places to be displayed for Accel/
Decel functions.
Direct Access Number — F704
Parameter Type — Numeri cal
Factory Default — 0.1
Changeable During Run — Yes
Minimum — 1
Maximum — 0.01
Prohibit Initializing User Parameters During Typeform Initialization
Program Special Control Parameters Special Parameters
Prohibit Initializing User Parameters During Typeform Initialization
This parameter Enables/Disables the ability to initialize use r parameters during
a Type Form initialization.
Settings:
Allowed
Prohibited
Direct Access Number — F709
Parameter Type — Selection List
Factory Default — Allowed
Changeable During Run — Yes
V/f Group
No path available (Direct Access Only)
While operating using the LED Keypad Option 1 of 4 V/f groups may be
selected and run. E ach V/f group is comprised of 4 user-define d variables: Base
Frequency, Base Frequency Voltage, Manual Torq ue Boost, and Electronic
Thermal Protection. Expanded descriptions of these parameters may be found
in this section (Direct Access Parameter Information).
Settings:
Group 1
Group 2
Group 3
Group 4
Note: If using the LCD EOI, press ESC from the Frequency
Command screen to access this parameter.
Direct Access Number — F720
Parameter Type — Selection List
Factory Default — 1
Changeable During Run — Yes
Stop Pattern
No path available (Direct Access Only)
While operating using the LED Keypad Option the Stop Pattern pa rameter
determines the method used to stop the motor when the stop command is issued
via a Stop command from the LED Keypad.
The Decel Stop setting enables the Dynamic Braking system that is setup at
F304 or the DC Injection Braking system tha t is setup at F250, F251, and
F252.
The Coast Stop setting allows the motor to stop a t the rate allowed by the
inertia of the load.
Settings:
Decel Stop
Coast Stop
Note: The Stop Pattern setting has no effect on the Emergency Off
settings of F603. If using the LCD EOI, press ESC from the
Frequency Command screen to access this pa rameter.
Direct Access Number — F721
Parameter Type — Selection List
Factory Default — Decel Stop
Changeable During Run — Yes
F704 F721