Toshiba G7 Undervoltage, Ridethrough, Overload, Trip Settings, Cooling Fan Control, Phase Loss

Models: G7

1 221
Download 221 pages 24.99 Kb
Page 58
Image 58

Program Menu Navigation

Primary Menu

Sub Menu

Parameter Name

Parameter

Number

 

 

 

 

 

 

 

 

 

 

 

PROTECTION

 

Ridethrough Mode

F302

 

 

 

PARAMETERS

Undervoltage/

Ridethrough Time

F310

 

Undervoltage Stall Level

F629

 

Ridethrough

 

 

 

 

 

Undervoltage Trip Enable/Disable

F627

 

 

 

 

 

 

Undervoltage Detection Time

F628

 

 

 

 

 

 

OL Reduction Starting Frequency

F606

 

 

 

 

 

 

Motor 150% OL Time Limit

F607

 

Overload

 

 

 

Soft Stall Enable/Disable

F017

 

 

 

 

 

 

Motor Overload Trip Enable/Disable

N/A

 

 

 

 

 

 

V/f Motor Enable/Disable

N/A

 

 

 

 

 

Trip Settings

Trip Save at Power Down Enable/Disable

F602

 

 

 

 

 

Cooling Fan Control

Cooling Fan Control Mode

F620

 

 

 

 

 

Cumulative Run Timer

Cumulative Run Timer Alarm Setting

F621

 

 

 

 

 

Phase Loss

Output Phase Loss Detection Enable/Disable

F605

 

 

 

 

 

Low Current Settings

Low Current Trip/Alarm Configuration

F610

 

 

 

 

 

 

Abnormal Speed Detection Filter Time

F622

 

Abnormal Speed Settings

 

 

 

Overspeed Detection Frequency Range

F623

 

 

 

 

 

 

Speed Drop Detection Frequency Range

F624

 

 

 

 

 

Short Circuit Detect Pulse

Short-Circuit-Pulse Run Command

F613

 

 

 

 

Short-Circuit-Pulse Run Duration

F614

 

 

 

 

 

 

 

 

Overtorque Trip Enable/Disable

F615

 

 

 

 

 

 

Overtorque Trip/Alarm Level During Power

F616

 

 

Operation

 

Overtorque Settings

 

 

 

 

 

Overtorque Trip/Alarm Level During

F617

 

 

 

 

Regeneration

 

 

 

 

 

 

 

 

 

Overtorque Detection Time

F618

 

 

 

 

 

Brake Fault Timer

Braking Trouble Internal Timer

F630

 

 

 

 

Release After Run Timer

F632

 

 

 

 

 

 

 

Base Frequency Voltage

Supply Voltage Compensation Enable/Disable

F307

 

 

 

 

Output Voltage Limitation Enable/Disable

 

 

 

 

 

 

 

 

 

Soft Start

Suppression of Inrush-Current Timing

F609

 

 

 

 

Interlock with ST

 

 

 

 

 

 

 

 

TORQUE SETTING

 

VI/II

F205

Set Points

 

 

PARAMETERS

RR

F214

 

 

RX

F220

 

 

 

 

 

Set Points

RX2

F226

 

 

 

 

BIN

F232

 

 

 

 

 

 

 

 

Torque Command Selection

F420

 

Torque Control

 

 

 

Torque Command Filter

F421

 

 

 

 

 

 

Synchronized Torque Bias Input Selection

F422

 

 

 

 

52

G7 ASD Operation Manual

Page 58
Image 58