Program Menu Navigation

Primary Menu

Sub Menu

Parameter Name

Parameter

Number

 

 

 

 

 

 

 

 

 

 

 

FREQUENCY SETTING

 

#5 Frequency & Characteristics

F022

 

 

 

PARAMETERS

 

#6 Frequency & Characteristics

F023

 

 

#7 Frequency & Characteristics

F024

 

 

 

 

 

 

#8 Frequency & Characteristics

F287

 

 

 

 

 

 

#9 Frequency & Characteristics

F288

 

Preset Speeds

 

 

 

#10 Frequency & Characteristics

F289

 

 

 

 

 

 

#11 Frequency & Characteristics

F290

 

 

 

 

 

 

#12 Frequency & Characteristics

F291

 

 

 

 

 

 

#13 Frequency & Characteristics

F292

 

 

 

 

 

 

#14 Frequency & Characteristics

F293

 

 

 

 

 

 

#15 Frequency & Characteristics

F294

 

 

 

 

 

Preset Speed Mode

Use Preset Speed Enable/Disable

F380

 

 

 

 

 

Fwd/Rev Disable

Disable Forward Run/Disable Reverse Run

F311

 

 

 

 

 

 

Motorized Pot Setting Disposition at Power

F108

 

 

Down

 

Motorized Pot Settings

 

 

 

 

 

Minimum Frequency

N/A

 

 

 

 

 

 

 

 

Maximum Frequency

N/A

 

 

 

 

PROTECTION

Dynamic Braking

Dynamic Braking Enable/Disable &

F304

Configuration

PARAMETERS

 

 

 

 

 

 

Over-current Stall Level

F601

 

 

 

 

 

 

 

 

Over-voltage Stall Enable/Disable

F305

 

 

 

 

 

 

Over-voltage Stall Level Configuration

N/A

 

Stall

 

 

 

Over-voltage Stall Level (Fast)

F625

 

 

 

 

 

 

Continuing Stall Period (During Positive

F452

 

 

Torque/Speed)

 

 

 

 

 

 

 

 

 

Stall Prevention During Regeneration

F454

 

 

 

 

 

 

Start Frequency

F250

 

 

 

 

 

 

DC Braking Current

F251

 

DC (Injection) Braking

 

 

 

DC Braking Time

F252

 

 

 

 

 

 

Motor Shaft Fixing Control

F253

 

 

 

 

 

 

Motor Shaft Stationary Control Enable/Disable

F254

 

 

 

 

 

 

Emergency Off Mode Configuration

F603

 

 

 

 

 

Emergency Off Settings

DC Injection Braking Time

F604

 

 

 

 

 

Emergency Off Activation of the FL Output

N/A

 

 

Enable/Disable

 

 

 

 

 

 

 

 

 

Number of Retries

F303

 

 

 

 

 

 

Restart Conditions

F301

 

 

 

 

 

Retry/Restart

Scan Rate

F312

 

Configuration

 

 

 

Lock-on Rate

F313

 

 

 

 

 

 

Search Method

F314

 

 

 

 

 

 

Search Inertia

F315

 

 

 

 