F471 | F474 |
VI/II Gain Adjust
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference Setpoints ⇒ VI/II ⇒ Gain
This parameter is used to fine tune the gain of the VI/II input terminals.
Note: See note on pg. 46 for further information on the VI/II terminal.
This setting may be used to ensure that the 100% level of the input source (pot, pressure transducer, flow meter, etc.) is also the 100% level setting of the ASD system.
This is accomplished by setting the input source to 100% and either increasing or decreasing this setting to provide an output of 100% from the ASD.
Direct Access Number — F471
Parameter Type — Numerical
Factory Default — 50
Changeable During Run — Yes
Minimum — 0.0
Maximum — 255
RR Bias Adjust
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference Setpoints ⇒ RR ⇒ Bias
This parameter is used to fine tune the bias of the RR input terminal when this terminal is used as the control input while operating in the Speed Control or the Torque Control mode.
This setting may be used to ensure that the zero level of the input source (pot, pressure transducer, flow meter, etc.) is also the zero level setting of the ASD system.
This is accomplished by setting the input source to zero and either increasing or decreasing this setting to provide an output of zero from the ASD.
Direct Access Number — F472
Parameter Type — Numerical
Factory Default — 120
Changeable During Run — Yes
Minimum — 0.0
Maximum — 255
RR Gain Adjust | Direct Access Number — | F473 |
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference | Parameter Type — Numerical | |
Setpoints ⇒ RR ⇒ Gain | Factory Default — 61 |
|
This parameter is used to fine tune the gain of the RR input terminal when this | Changeable During Run — Yes | |
|
| |
terminal is used as the control input while operating in the Speed Control or | Minimum — 0.0 |
|
the Torque Control mode. | Maximum — 255 |
|
|
| |
This setting may be used to ensure that the 100% level of the input source (pot, |
|
|
pressure transducer, flow meter, etc.) is also the 100% level setting of the ASD |
|
|
system. |
|
|
This is accomplished by setting the input source to 100% and either increasing |
|
|
or decreasing this setting to provide an output of 100% from the ASD. |
|
|
|
|
|
RX Bias Adjust | Direct Access Number — | F474 |
Program ⇒ Frequency Setting Parameters ⇒ Speed Reference | Parameter Type — Numerical | |
Setpoints ⇒ RX ⇒ Bias | Factory Default — 99 |
|
This parameter is used to fine tune the bias of the RX input terminal when this | Changeable During Run — Yes | |
|
| |
terminal is used as the control input while operating in the Speed Control or | Minimum — 0.0 |
|
the Torque Control mode. | Maximum — 255 |
|
|
|
This setting may be used to ensure that the zero level of the input source (pot, pressure transducer, flow meter, etc.) is also the zero level setting of the ASD system.
This is accomplished by setting the input source to zero and either increasing or decreasing this setting to provide an output of zero from the ASD.
136 | G7 ASD Operation Manual |