F327 | F331 |
Drooping Reference
Program ⇒ Feedback Parameters ⇒ Drooping Control ⇒ Drooping
Reference
This parameter sets the method to be used in determining the output torque while operating in the Drooping Control mode.
Settings:
Direct Access Number — F327
Parameter Type — Selection List
Factory Default — Total torque calculated by the detection current
Changeable During Run — Yes
Total Torque Calculated by the Detection Current.
Torque without Acc/Dec Torque Calculated by Detection Current. Total Torque Calculated by the Command Current.
Torque without Acc/Dec Torque Calculated by the Command Current.
Light-load High-speed Operation Selection
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ Express Speed Settings ⇒
This parameter enables the
F341.
Direct Access Number — F330
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Minimum — 30.0
Maximum — Upper Limit (F012) Units — Hz
This parameter may be disabled.
If either of the other selections are made and configured, and after the criteria of F331 – F333 are met, the
Settings:
Disabled
Reserved
Automatic Enable - Automatic Speed (F341)
Automatic Enable - Preset Speed (Preset IDBin is OR’ed w/1000Bin) Discrete Enable - Automatic Speed (F341) (see item 60 of Table 8 on pg. 76) Discrete Enable - Preset Speed (Preset IDBin is OR’ed w/1000Bin) (see item 60 of Table 8 on pg. 76)
| Direct Access Number — F331 | |
Frequency | Parameter Type — Numerical | |
Program ⇒ Special Control Parameters ⇒ Crane/Hoist Settings ⇒ | Factory Default — 40.00 | |
Express Speed Settings ⇒ | Changeable During Run — Yes | |
Switching | ||
Minimum — 30.0 | ||
| ||
This parameter sets an output frequency threshold that, once surpassed, allows | Maximum — Upper Limit (F012) | |
the | Units — Hz | |
| ||
The |
| |
(F331) and the following conditions are met: |
| |
1) |
| |
2) The output torque is less than the setting established in F335 when reaching |
| |
the frequency setting here. |
|
G7 ASD Operation Manual | 117 |