F103 | F105 |
ST Signal Selection
Program ⇒ Terminal Selection Parameters ⇒ Input Special Functions
This parameter is used to set the operation of the Standby (ST) control terminal or any terminal configured as the ST terminal.
Settings:
Interlock with F/R Terminal
The setting
The
The Interlock with F/R Terminal setting configures the F (Forward) and R (Reverse) control terminals for the secondary function of Standby. Closing a set of contacts to either F or R will cause the ASD to accelerate the motor to the programmed setpoint of F or R. Opening the F and R contact will disable the ASD and the motor will coast to a stop. The control terminal ST may be configured for other functions.
Direct Access Number — F103 Parameter Type — Selection List Factory Default — ST – CC Required Changeable During Run — No
R/F Priority Selection
Program ⇒ Terminal Selection Parameters ⇒ Input Special Functions
The R/F Priority Selection determines the operation of the ASD if both the R and F control terminals are activated.
Settings:
Reverse
Suspend
The waveforms below depict the motor response for all combinations of the F and R terminal settings if the Reverse option is chosen.
The Suspend setting will decelerate the motor to a stop regardless of the rotation direction when both the F and R control terminals are activated.
Direct Access Number — F105
Parameter Type — Selection List
Factory Default — Reverse
Changeable During Run — No
G7 ASD Operation Manual | 69 |