F375 |
| F379 | |
|
|
| |
Current Control Integral Gain | Direct Access Number — | F375 | |
Program ⇒ Feedback Parameters ⇒ PG Settings | Parameter Type — Numerical | ||
This parameter sets the degree and rate at which the output frequency will be | Factory Default — | ||
Changeable During Run — No | |||
allowed to change when prompted by changes in the output current. | |||
|
| ||
The larger the value entered here, the quicker/more the drive responds to | Minimum — 100.0 |
| |
|
| ||
changes in feedback. | Maximum — 1250 |
| |
|
|
| |
Speed Loop Proportional Gain | Direct Access Number — | F376 | |
Program ⇒ Feedback Parameters ⇒ PG Settings | Parameter Type — Numerical | ||
This parameter sets the Proportional Gain (sensitivity) of the drive when | Factory Default — | ||
Changeable During Run — Yes | |||
monitoring the PG signal to control speed. The larger the value entered here, | |||
|
| ||
the more sensitive the drive is to changes in the received feedback and the | Minimum — 3.2 |
| |
quicker it responds. | Maximum — 1000 |
| |
|
| ||
|
|
| |
Speed Loop Integral Gain | Direct Access Number — | F377 | |
Program ⇒ Feedback Parameters ⇒ PG Settings | Parameter Type — Numerical | ||
This parameter sets the response time of the Speed Loop Integral Gain. The | Factory Default — | ||
Changeable During Run — Yes | |||
smaller the value here, the more pronounced (quicker) the effect of the integral | |||
|
| ||
function. | Minimum — 10.0 |
| |
| Maximum — 200.0 |
| |
|
|
| |
Motor Counter Data | Direct Access Number — | F378 | |
Program ⇒ Feedback Parameters ⇒ PG Settings | Parameter Type — Selection List | ||
This parameter sets the | Factory Default — Selection 0 | ||
Changeable During Run — No | |||
when using a | |||
|
| ||
display purposes only and does not affect the speed control of the system. | Minimum — Selection 0 |
| |
If zero is selected here then the setting at F370 (Electronic Gear Setting) | Maximum — Selection 5 |
| |
determines the |
|
| |
Settings: |
|
| |
Selection 0 — F370 setting |
|
| |
Selection 1 — 256 pulses/revolution |
|
| |
Selection 2 — 512 pulses/revolution |
|
| |
Selection 3 — 1024 pulses/revolution |
|
| |
Selection 4 — 2048 pulses/revolution |
|
| |
Selection 5 — 4096 pulses/revolution |
|
| |
|
|
| |
Speed Loop Parameter Ratio | Direct Access Number — | F379 | |
Program ⇒ Feedback Parameters ⇒ PG Settings | Parameter Type — Numerical | ||
| Factory Default — 1.00 |
|
Contact Toshiba’s Marketing Department for information on this parameter.
Changeable During Run — No Minimum — 0.01 Maximum — 10.00
124 | G7 ASD Operation Manual |