F018 |
|
|
|
|
|
| F019 | ||
|
|
|
|
|
|
|
|
| |
Preset Speed #1 | Direct Access Number — | F018 | |||||||
Program ⇒ Pattern Run Control ⇒ Preset Speeds ⇒ 1 | Parameter Type — Numerical |
|
| ||||||
Up to 15 output frequency values that fall within the Lower Limit and the | Factory Default — 0.0 |
|
|
| |||||
|
|
|
|
|
|
|
| ||
Upper Limit range may be programmed into the drive and output as a Preset | Changeable During Run — Yes |
|
| ||||||
Speed. This parameter assigns an output frequency to binary number 0001 and | Minimum — Lower Limit (F013) | ||||||||
is identified as Preset Speed #1. The binary number is applied to S1 – S4 of the | |||||||||
Maximum — Upper Limit (F012) | |||||||||
Control Terminal Strip to output the Preset Speed. | |||||||||
Perform the following setup to allow the system to receive Preset Speed | Units — Hz |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
control input at the S1 – S4 terminals: |
|
|
|
|
|
|
|
| |
1. Program ⇒ Fundamental Parameters ⇒ Standard Mode Selection ⇒ Use | Preset | S4 | S3 | S2 |
| S1 | Output |
| |
MSB | LSB |
| |||||||
Control Terminal Strip. |
|
|
|
|
|
|
|
| |
1 | 0 | 0 | 0 |
| 1 | F018 |
| ||
2. Program ⇒ Terminal Selection Parameters ⇒ Input Terminals ⇒ S1 (set to |
|
| |||||||
2 | 0 | 0 | 1 |
| 0 | F019 |
| ||
Preset Speed Command 1; LSB of |
|
|
|
|
|
|
|
| |
3 | 0 | 0 | 1 |
| 1 | F020 |
| ||
of |
|
|
|
|
|
|
|
| |
4 | 0 | 1 | 0 |
| 0 | F021 |
| ||
Normally Open). |
|
| |||||||
|
|
|
|
|
|
|
| ||
5 | 0 | 1 | 0 |
| 1 | F022 |
| ||
|
|
| |||||||
|
|
|
|
|
|
|
|
| |
Note: The default setting of S4 is EOff, but this terminal may be re- | 6 | 0 | 1 | 1 |
| 0 | F023 |
| |
|
|
|
|
|
|
|
| ||
assigned as the MSB. | 7 | 0 | 1 | 1 |
| 1 | F024 |
| |
|
|
|
|
|
|
|
| ||
3. Program ⇒ Frequency Setting Parameters ⇒ Preset Speeds ⇒ 1 (press | 8 | 1 | 0 | 0 |
| 0 | F287 |
| |
|
|
|
|
|
|
|
| ||
9 | 1 | 0 | 0 |
| 1 | F288 |
| ||
Enter twice and set an output frequency as Preset Speed #1; repeat for |
|
|
|
|
|
|
|
| |
10 | 1 | 0 | 1 |
| 0 | F289 |
| ||
Preset Speeds 2 – 15 as required). |
|
|
|
|
|
|
|
| |
11 | 1 | 0 | 1 |
| 1 | F290 |
| ||
|
|
| |||||||
|
|
|
|
|
|
|
|
| |
4. Program ⇒ Frequency Setting Parameters ⇒ Preset Speed Mode ⇒ Use | 12 | 1 | 1 | 0 |
| 0 | F291 |
| |
Speed Modes (Enable/Disable). | 13 | 1 | 1 | 0 |
| 1 | F292 |
| |
|
|
|
|
|
|
|
|
| |
When Enabled, the direction, accel/decel, and torque settings of the | 14 | 1 | 1 | 1 |
| 0 | F293 |
| |
|
|
|
|
|
|
|
| ||
15 | 1 | 1 | 1 |
| 1 | F294 |
| ||
Preset Speed being run are used. |
|
| |||||||
|
|
|
|
|
|
|
| ||
Note: 1 = Terminal connected to CC. |
| ||||||||
When Disabled, only the speed setting of the Preset Speed being run is |
| ||||||||
|
|
|
|
|
|
|
| ||
used. |
|
|
|
|
|
|
|
| |
5. Place the system in the Remote mode (LocalRemote LED Off). |
|
|
|
|
|
|
|
| |
6. Provide a Run command (connect F and/or R to CC). |
|
|
|
|
|
|
|
| |
Connect S1 to CC to run Preset Speed #1 (S1 to CC = 0001 binary). |
|
|
|
|
|
|
|
| |
With S1 – S4 configured to output Preset Speeds (F115 – F118), 0001 – 1111 |
|
|
|
|
|
|
|
| |
may be applied to S1 – S4 of the Control Terminal Strip to run the associated |
|
|
|
|
|
|
|
| |
Preset Speed. If bidirectional operation is required, F and R must be connected |
|
|
|
|
|
|
|
| |
to CC, and Use Speed Modes must be enabled at F380. |
|
|
|
|
|
|
|
| |
With S1 being the least significant bit of a binary count, the S1 – S4 settings |
|
|
|
|
|
|
|
| |
will produce the programmed speed settings as indicated below. |
|
|
|
|
|
|
|
| |
Preset Speeds are also used in the Pattern Run mode. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Preset Speed #2 | Direct Access Number — | F019 | |||||||
Program ⇒ Pattern Run Control ⇒ Preset Speeds ⇒ 2 | Parameter Type — Numerical |
|
| ||||||
This parameter assigns an output frequency to binary number 0010 and is | Factory Default — 0.0 |
|
|
| |||||
Changeable During Run — Yes |
|
| |||||||
identified as Preset Speed #2. The binary number is applied to S1 – S4 of the |
|
| |||||||
Minimum — Lower Limit (F013) | |||||||||
Control Terminal Strip to output the Preset Speed (see F018 for further | |||||||||
information on this parameter). | Maximum — Upper Limit (F012) | ||||||||
|
Units — Hz
66 | G7 ASD Operation Manual |