F451

 

F470

 

 

 

Torque Limit Mode (Speed Dependent)

Direct Access Number —

F451

Program Torque Setting Parameters Torque Limit Settings

Parameter Type — Selection List

Torque Limit Mode (Speed Dependent)

Factory Default — Standard

This parameter allows for either wide or very limited speed fluctuations while

Changeable During Run — Yes

 

 

operating in the Torque Control mode.

 

 

The ASD output follows the commanded speed when No Speed Cooperation

 

 

is selected and has a very limited speed fluctuation range when Standard is

 

 

selected.

 

 

Settings:

 

 

Standard

 

 

No Speed Cooperation

 

 

 

 

 

Continued Stall Until Trip During Power Operation

Direct Access Number —

F452

Program Protection Parameters Stall Continuing Stall Period

Parameter Type — Numerical

This parameter allows the user to extend the Overvoltage Stall (F305) and the

Factory Default — 0.0

 

Changeable During Run — Yes

Overcurrent Stall (F017) time settings.

 

 

 

Minimum — 0.0

 

 

Maximum — 1.00

 

 

Units — Seconds

 

 

 

 

Stall Prevention During Regeneration

Direct Access Number —

F453

Program Protection Parameters Stall Stall Prevention During

Parameter Type — Selection List

Regeneration

Factory Default — With Stall

This parameter Enables/Disables the Overvoltage Stall (F305) and the

Prevention.

 

Changeable During Run — Yes

Overcurrent Stall (F017) function during regeneration only. Application-

 

 

specific conditions may occur that warrant disabling the Stall function during

 

 

regeneration.

 

 

Settings:

 

 

With Stall Prevention

 

 

Without Stall Prevention

 

 

 

 

 

Current Differential Gain

Direct Access Number —

F454

Program Special Control Parameters Special Parameters

Parameter Type — Numerical

Current Differential Gain

Factory Default — 1.23

 

This parameter determines the degree that the current differential function

Changeable During Run — Yes

 

 

affects the output signal. The larger the value entered here, the more

Minimum — 0.00

 

pronounced the Current Differential Gain.

Maximum — 327.6

 

 

 

 

 

 

VI/II Bias Adjust

Direct Access Number —

F470

Program Frequency Setting Parameters Speed Reference

Parameter Type — Numerical

Setpoints VI/II Bias

Factory Default — 100

 

This parameter is used to fine-tune the bias of the VI/II input terminals.

Changeable During Run — Yes

Minimum — 0.0

Note: See note on pg. 46 for further information on the VI/II terminal.

Maximum — 255

This setting may be used to ensure that the zero level of the input source (pot, pressure transducer, flow meter, etc.) is also the zero level setting of the ASD system.

This is accomplished by setting the input source to zero and either increasing or decreasing this setting to provide an output of zero from the ASD.

G7 ASD Operation Manual

135

Page 141
Image 141
Toshiba G7 manual Torque Limit Mode Speed Dependent, Stall Until Trip During Power Operation, Current Differential Gain