Table 16. (Continued) 460 Volt NEMA Type-1/IP-20 Chassis standard ratings table.

 

 

 

Input Voltage

Output Voltage

Output

Overload

Overload

Overload

Model

Rated

Motor

Current

Current

Current

VT130G7U

KVA

HP/Kw

3-Ph 50/60

3-Ph Variable

Current 100/

130% for

150% for

150% for

± 2 Hz

Frequency

110% Cont.

 

 

 

120 Secs.

60 Secs.

120 Secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4270B

27.0

25.0/18.5

 

Input Voltage Level

38.0/41.8 A

 

 

57.0 A

 

 

 

 

(Max.)

 

 

 

 

4330B

33.0

30.0/22.0

 

45.0/49.5 A

 

 

67.5 A

 

 

 

 

 

 

 

 

 

4400B

40.0

40.0/30.0

 

 

57.0/62.7 A

 

 

85.5 A

 

 

 

 

 

 

 

 

 

4500B

50.0

50.0/37.0

 

 

71.0/78.1 A

 

 

106.5 A

 

 

 

 

 

 

 

 

 

* 4600B

60.0

60.0/45.0

 

 

83.0/91.3 A

 

 

124.5 A

 

 

 

 

 

 

 

 

 

* 4750B

75.0

75.0/55.0

 

 

104.0/114.4 A

 

 

156.0 A

 

 

 

380 – 480 VAC

 

 

 

 

 

* 410KB

100

100/75.0

 

138.0/151.8 A

 

 

207.0 A

(±10%)

 

 

 

 

 

 

 

 

 

 

 

* 412KB

125

125/90.0

 

172.0/189.2 A

 

258.0 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* 415KB

150

150/110

 

 

206.0/226.6 A

 

309.0 A

 

 

 

 

 

 

 

 

 

 

* 420KB

200

200/150

 

 

275.0/302.5 A

 

412.5 A

N/A

 

 

 

 

 

 

 

 

* 425KB

250

250/185

 

 

343.0/377.3 A

 

514.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

* 430KB

300

300/220

 

 

415.0/456.5 A

 

622.5 A

 

 

 

 

 

 

 

 

 

 

* 435KB

350

350/243

 

 

447.0/491.7 A

586.8 A

670.5 A

 

 

 

 

 

 

 

 

 

 

Note: *12-Pulse option available.

Table 17. 600 Volt NEMA Type-1/IP-20 Chassis standard ratings table.

Model

Rated

Motor

Input Voltage

Output Voltage

Output

Overload

Overload

3-Ph 50/60

3-Ph Variable

Current 100/

Current 150%

Current 150%

VT130G7U

KVA

HP/Kw

±2 Hz

Frequency

110% Cont.

for 60 Secs.

for 120 Secs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6015B

1.5

1.0/0.75

 

 

2.1/2.3 A

 

 

3.2 A

 

 

 

 

 

 

 

 

 

6025B

2.5

2.0/1.5

 

 

3.0/3.3 A

 

 

4.5 A

 

 

 

 

 

 

 

 

 

6035B

3.5

3.0/2.2

495 – 600 VAC

 

4.0/4.4 A

 

 

6.0 A

 

 

 

 

 

 

 

 

6060B

6.0

5.0/3.7

 

6.1/6.7 A

 

 

9.2 A

(+5/-10%)

 

 

 

 

 

 

 

 

 

 

 

6080B

8.0

7.5/5.0

 

9.0/9.9 A

 

 

13.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

6110B

11.0

10.0/7.5

 

 

12.0/13.2 A

 

 

18.0 A

 

 

 

 

 

 

 

 

 

6160B

16.0

15.0/11.2

 

 

17.0/18.7 A

 

 

25.5 A

 

 

 

 

 

 

 

 

 

6220B

22.0

20.0/14.9

 

 

22.0/24.2 A

N/A

33.0 A

 

 

 

 

 

 

 

 

 

6270B

27.0

25.0/18.5

 

Input Voltage Level

27.0/29.7 A

 

 

40.5 A

 

 

 

 

 

 

 

 

6330B

33.0

30.0/22.0

 

32.0/35.2 A

 

 

48.0 A

 

(Max.)

 

 

 

 

 

 

 

 

 

 

6400B

40.0

40.0/30.0

 

41.0/45.1 A

 

 

61.5 A

 

 

 

 

 

 

 

 

 

 

 

 

 

6500B

50.0

50.0/37.0

 

 

52.0/57.2 A

 

 

78.0 A

 

 

 

 

 

 

 

 

 

6600B

60.0

60.0/45.0

495 – 600 VAC

 

62.0/68.2 A

 

 

93.0 A

 

 

 

(±10%)

 

 

 

 

 

6750B

75.0

75.0/55.0

 

77.0/84.7 A

 

 

115.5 A

 

 

 

 

 

 

 

 

 

* 610KB

100

100/75.0

 

 

99.0/108.9 A

 

 

148.5 A

 

 

 

 

 

 

 

 

* 612KB

125

125/90.0

 

 

125.0/137.5 A

187.5 A

 

 

 

 

 

 

 

 

 

* 615KB

150

150/110

 

 

150.0/165.0 A

225.0 A

N/A

 

 

 

 

 

 

 

 

* 620KB

200

200/150

 

 

200.0/220.0 A

300.0 A

 

 

 

 

 

 

 

 

 

 

 

* 625KB

250

250/185

 

 

250.0/275.0 A

375.0 A

 

 

 

 

 

 

 

 

 

* 630KB

300

300/224

 

 

289.0/317.9 A

433.5 A

 

 

 

 

 

 

 

 

 

 

Note: *12-Pulse option available.