Toshiba G7 manual Preset Speed #10, Preset Speed #11, Preset Speed #12, Preset Speed #13

Models: G7

1 221
Download 221 pages 24.99 Kb
Page 116
Image 116

F289

F294

Preset Speed #10

Program Pattern Run Control Preset Speeds 10

This parameter assigns an output frequency to binary number 1010 and is identified as Preset Speed #10. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F289

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz

Preset Speed #11

Program Pattern Run Control Preset Speeds 11

This parameter assigns an output frequency to binary number 1011 and is identified as Preset Speed #11. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F290

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz

Preset Speed #12

Program Pattern Run Control Preset Speeds 12

This parameter assigns an output frequency to binary number 1100 and is identified as Preset Speed #12. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F291

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz

Preset Speed #13

Program Pattern Run Control Preset Speeds 13

This parameter assigns an output frequency to binary number 1101 and is identified as Preset Speed #13. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F292

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz

Preset Speed #14

Program Pattern Run Control Preset Speeds 14

This parameter assigns an output frequency to binary number 1110 and is identified as Preset Speed #14. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F293

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz

Preset Speed #15

Program Pattern Run Control Preset Speeds 15

This parameter assigns an output frequency to binary number 1111 and is identified as Preset Speed #15. The binary number is applied to S1 S4 of the Control Terminal Strip to output the Preset Speed (see F018 for further information on this parameter).

Direct Access Number — F294

Parameter Type — Numerical

Factory Default — 0.00

Changeable During Run — Yes

Minimum — Lower Limit (F013)

Maximum — Upper Limit (F012)

Units — Hz