F812 | F820 |
Communications Speed Setpoint #1 (frequency)
Program ⇒ Communication Setting Parameters ⇒ Communication
Reference Adjust
This parameter is used to set the gain and bias of the Communications Reference speed control input.
See F811 for further information on this setting.
This parameter sets Communications Reference Speed Setpoint #1.
Changes made to this parameter require that the power be cycled (Off then On) for the changes to take effect.
Direct Access Number — F812
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — Hz
Communications Reference Setpoint #2 (%) | Direct Access Number — | F813 |
Program ⇒ Communication Setting Parameters ⇒ Communication | Parameter Type — Numerical | |
Reference Adjust | Factory Default — 100.0 |
|
This parameter is used to set the gain and bias of the Communications | Changeable During Run — Yes | |
|
| |
Reference speed control input. | Minimum — 0.00 |
|
See F811 for further information on this setting. | Maximum — 100.0 |
|
This parameter sets the Communications Reference input value that represents | Units — % |
|
|
| |
Communications Reference Speed Setpoint #2 (frequency). This value is |
|
|
entered as 0 to 100% of the Communications Reference input value range. |
|
|
Changes made to this parameter require that the power be cycled (Off then On) |
|
|
for the changes to take effect. |
|
|
|
|
|
Communications Speed Setpoint #2 (frequency) | Direct Access Number — | F814 |
Program ⇒ Communication Setting Parameters ⇒ Communication | Parameter Type — Numerical | |
Reference Adjust | Factory Default — 80.0 |
|
This parameter is used to set the gain and bias of the Communications | Changeable During Run — Yes | |
|
| |
Reference speed control input. | Minimum — 0.0 |
|
See F811 for further information on this setting. | Maximum — Max. Freq. (F011) | |
This parameter sets the Communications Reference Speed Setpoint #2. | Units — Hz |
|
Changes made to this parameter require that the power be cycled (Off then On) |
|
|
for the changes to take effect. |
|
|
|
|
|
RS232/RS485 Baud Rate | Direct Access Number — | F820 |
Program ⇒ Communication Setting Parameters ⇒ Communication | Parameter Type — Selection List | |
Settings | Factory Default — 9600 |
|
This parameter sets the RS232/RS485 baud rate.
Changeable During Run — Yes
Changes made to this parameter require that the power be cycled (Off then On) for the changes to take effect.
Settings:
1200
2400
4800
9600
19200
38400
G7 ASD Operation Manual | 171 |