G7 ASD Operation Manual 43
System Configuration and Menu Options

Root Menus

The MON/PRG key accesses the three primary mode s of the G7: the Frequency C ommand mode, the
Monitor mode, and the Program mode. From either mode, press the MON/PRG key to loop through to
the other two modes (see Figure 21). While in the Frequency Command mode, pressing the ESC key
toggles the menu to and from the Panel menu and the Frequency Comma nd mode.
Note: Panel menu changes made when accessing the Panel menu using the method shown in
Figure 21 is effective for Local LCD EOI control Only.
Figure 21. Root menu mapping.

Frequency Command Mode

Frequency Setting
While operating in the Local mode (Local LED is illuminated on the front panel), the running frequency
of the motor may be set from the Frequency Command screen. Using the Ro t a ry En coder, enter the
Frequency Command value and then press the Run key. The motor will run at the Frequency
Command speed and may be changed while running.
Scrolling Monitor
The Output Current and the ASD Load values are displayed (default setting) below the Frequency
Command parameter of the Frequency Command screen. Other user-selected parameters may be
displayed on this screen for quick-access monitoring while running. These parameters may be accessed
and enabled for display by placing a check in the box next to the item listed at Program Monitor Setup
Scrolling Monitor Select. If no parameters are enabled for display, No Items is displayed.
When more than two items are selected for display the items are scrolled automatically. The display time
for each selected item may be set from 1 to 60 seconds. The parameters that may be displayed on the
Scrolling Monitor are listed in the section titled Monitor Mode on pg. 45.