PG Position — Displays the Pulse Generator Position.

RR— Displays the RR input value as a percentage of the full range of the RR value (potentiometer input).

*VI/II — Displays the VI/II input setting as a percentage of the full range of the VI/II value.

Note: * The VI/II input represents two analog inputs (and terminals). The VI input terminal is used for a 0 – 10 VDC analog signal and the II input terminal is used for current loop applications, such as with a 4-20 mA signal. Either may be used as a frequency or torque command source; however, the two cannot function simultaneously. Throughout this manual they will be listed as VI/II.

RX — Displays the RX input setting as a percentage of the full range of the RX value (-10 to +10 VDC input).

RX2 — Displays the RX2 input setting as a percentage of the full range of the RX2 value.

Note: The RX2 function is available on the ASD-Multicomoption board only.

FM — Displays the output frequency value as a percentage of the full range of the FM value. AM — Displays the output current as a percentage of the full range of the AM value.

Option Type — Displays the type form number of the installed ASD-Multicomoption board. Option Term A — TBD.

Option Term B — TBD.

Option Term O — TBD.

Option Term P — TBD.

Max. Output — TBD.

Pattern Select — Active Group Number and Speed Number separated by a period (e.g., 2.3). Repeats Left — Number of remaining Speed cycles in the active Group.

Pattern — Active Speed Number of the Group.

Pattern Time Left — Time remaining in the active Speed.

Fault Status — Displays the current fault or No Fault.

46

G7 ASD Operation Manual