5DATA USED FOR POSITIONING CONTROL

(3)A phase/B phase mode

MELSEC-Q

Forward run and reverse run are controlled with the phase difference of the A phase (A) and B phase (B).

When the B phase is 90° behind the A phase, the motor will forward run.

When the B phase is 90° ahead of the A phase, the motor will reverse run.

Positive logic

Negative logic

 

 

 

 

1) For multiple of 1 setting

 

1) For multiple of 1 setting

 

Forward run

Reverse run

Forward run

Reverse run

Command pulse output

Command pulse output

Command pulse output

Command pulse output

A phase

(A

)

B phase

(B

)

When B phase is

When B phase is

When B phase is

When B phase is

90° behind A phase

90° ahead of A phase

90° behind A phase

90° ahead of A phase

2) For multiple of 4 setting

 

2) For multiple of 4 setting

 

Forward run

Reverse run

Forward run

Reverse run

Command pulse output

Command pulse output

Command pulse output

Command pulse output

A phase

(A

)

B phase (B )

When B phase is

When B phase is

When B phase is

When B phase is

90° behind A phase

90° ahead of A phase

90° behind A phase

90° ahead of A phase

Pr.6

Rotation direction setting

Set the relation of the motor rotation direction and current value address increment/decrement.

[Setting procedure]

1)Set "0" in Pr.6 , and carry out forward run JOG operation. ("0" is set as the default value for Pr.6 .)

2)When workpiece "W" moves toward the address increment direction, keep the current setting.

When workpiece "W" moves toward the address decrement direction, set "1" in Pr.6 to change the rotation direction.

3)Carry out forward run JOG operation again, and if "W" moves toward the increment direction, the setting is complete.

 

Address decre-

Address incre-

QD75

ment direction

ment direction

Motor

 

 

2) Workpiece

 

 

 

 

 

1) Forward run pulse

MW

OP3)

5 - 24

Page 112
Image 112