15 TROUBLESHOOTING

MELSEC-Q

Classification

Error

Error name

Error

Operation status at error occurrence

 

of errors

code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At start: The system will not operate.

 

 

 

 

• Positioning is carried out at a

In the analysis of new current value:

 

 

 

 

Current value is not

 

 

 

 

position beyond the software stroke

changed.

 

 

 

 

limit upper limit.

During operation:

 

 

 

 

• The positioning address and new

 

 

 

 

• The system stops

 

 

 

Software stroke

current value exceed the software

 

 

507

immediately when the

 

 

limit+

stroke limit upper limit.

 

 

 

 

• In the circular interpolation by the

positioning address during

 

 

 

 

position control (including

 

 

 

 

designation of the sub points, the

position control in speed-

 

 

 

 

sub points exceed the software

position switching control or

 

 

 

 

stroke limit upper limit.

position-speed switching

 

 

 

 

 

control) is switched to the

 

 

 

 

 

data outside the software

 

 

 

 

 

stroke limit range.

 

 

 

 

 

 

 

 

 

• The system makes a stop at

 

 

 

 

• Positioning is carried out at a

the setting (normal

 

 

 

 

deceleration stop only) of

 

 

 

 

position beyond the software stroke

sudden stop selection (stop

 

 

 

 

limit lower limit.

group 3) in the detailed

 

 

 

 

• The positioning address and new

parameter 2 when the

 

 

508

Software stroke

current value exceed the software

current feed value or

 

 

limit–

stroke limit lower limit.

machine feed value during

 

 

 

 

• In the circular interpolation by the

speed control (including

 

 

 

 

speed control in speed-

 

 

 

 

designation of the sub points, the

 

 

 

 

position switching control or

 

 

 

 

sub points exceed the software

 

 

 

 

position-speed switching

 

 

 

 

stroke limit lower limit.

 

 

 

 

control) or during manual

 

Positioning

 

 

 

 

 

 

 

control falls outside the

 

operation

 

 

 

software stroke limit range.

 

 

 

 

 

 

 

 

 

Outside new current

The new current address is outside

 

 

 

514

value range

the ranges of 0 to 359.99999, where

 

 

 

 

 

the control unit is set to "degree".

 

 

 

 

 

• The control system sets an

 

 

 

 

 

operation pattern (continuous path

 

 

 

 

 

control) using new current

The current value is not changed.

 

 

 

 

positioning data.

 

 

 

New current value

 

 

 

515

• The operation pattern sets a "new

 

 

 

 

not possible

current value" in the control system

 

 

 

 

 

 

 

 

 

 

using the data following the

 

 

 

 

 

"continuous path control"

 

 

 

 

 

positioning data.

 

 

 

 

 

• The continuous path control is

 

 

 

 

 

designated using a control system

 

 

 

 

 

which is not allowed to use for

 

 

 

 

 

continuous path control such as

 

 

 

 

 

speed control, speed-position

 

 

 

 

 

switching control, position-speed

 

 

 

 

Continuous path

switching control, and fixed-feed.

 

 

 

516

• The previous data such as those

At start, the system will not operate.

 

 

control not possible

 

 

 

 

on speed control, speed-position

 

 

 

 

 

switching control, position-speed

 

 

 

 

 

switching control, and fixed-feed

 

 

 

 

 

shows a continuous path control.

 

 

 

 

 

• The continuous positioning control

 

 

 

 

 

is designated for speed control or

 

 

 

 

 

position-speed switching control.

 

 

15 - 14