15 TROUBLESHOOTING

MELSEC-Q

 

Related buffer memory

 

Set range

 

 

 

address

 

 

Remedy

 

 

 

(Setting with sequence program)

 

Axis 1

Axis 2

Axis 3

Axis 4

 

 

 

 

 

 

 

 

 

 

 

 

 

1522

1622

1722

1822

<Manual pulse generator 1 pulse

Set the manual pulse generator 1 pulse input

 

1523

1623

1723

1823

 

input magnification>

magnification to within the setting range.

 

 

1 to 100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Speed change request>

Do not carry out the speed change during deceleration

 

1516

1616

1716

1816

with a stop command, during stoppage, or during

 

1: Speed change is requested

 

 

 

 

 

automatic deceleration with position control.

 

 

 

 

 

 

 

 

New speed value

0 to 1000000 [pulse/s]

 

 

1514

1614

1714

1814

 

 

0 to 2000000000 [mm/min or another]

 

 

1515

1615

1715

1815

 

 

 

 

Speed limit value

QD75P

:

 

 

 

 

 

 

1 to 200000 [pulse/s]

Set the new speed value to a range of 0 to "speed limit

 

 

 

 

 

1 to 2000000000

 

 

 

 

 

value".

 

 

 

 

 

[mm/min or another]

 

10

160

310

460

 

 

QD75D

:

 

 

11

161

311

461

1 to 1000000 [pulse/s]

 

 

 

 

 

 

 

 

 

 

 

 

1 to 2000000000

 

 

 

 

 

 

[mm/min or another]

 

 

 

 

 

 

 

 

 

1504

1604

1704

1804

<M code OFF request>

Normalize the ON and OFF timings of the "M code

 

1: M code ON signal is turned OFF

OFF request". (Refer to Section 12.7.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Operation pattern>

 

 

Refer to Section 5.3

00: Positioning complete

Set the operation termination to the 50th point.

 

"List of positioning data"

01: Continuous positioning control

(Refer to Chapter 10)

 

 

 

 

 

11: Continuous path control

 

 

 

 

 

 

 

 

 

 

 

Make 1 nest construction for FOR to NEXT.

 

 

(Refer to Section 10.3.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not turn ON the speed-position switching signal

 

 

during acceleration.

 

 

 

 

 

 

 

(Refer to Section 9.2.16)

 

 

 

 

 

 

 

 

 

 

Give a request at the position where there is an

 

 

enough remaining distance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Step start information>

Do not set a "1" to the step start information when the

 

1546

1646

1746

1846

 

1: Step is continued

 

 

step is not in standby state. (Refer to Section 12.7.1)

 

 

 

 

 

2: Re-start is carried out

 

 

 

 

 

 

 

 

 

 

 

<External command function

Set the detailed parameter 2 "External command

 

62

212

362

512

 

selection>

 

 

function selection" to within the setting range.

 

 

 

 

 

 

0, 1, 2, 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to Section 5.3

 

Set a decelerating address or a movement amount to

 

"List of positioning data"

 

the positioning data.

 

 

 

15 - 35

Page 639
Image 639
Mitsubishi Electronics QD75D Magnification to within the setting range, With a stop command, during stoppage, or during