12 - 95

MELSEC-Q
12 CONTROL SUB FUNCTIONS
[3] Deceleration start flag function setting method

To use the "deceleration start flag functio n", set "1" to the following control data

using a sequence program.

The set data is made valid on the rising edge (OF F to ON) of the PLC READY

signal [Y0].

Setting item Setting
value Setting details Buffer memory address
Cd.41 Deceleration start
flag valid
Set whether the deceleration start flag function
is made valid or invalid.
0: Deceleration start flag invalid
1: Deceleration start flag valid
1905
Refer to Section 5.7 "List of control data" for details on the setting details.
[4] Checking of deceleration start flag

The "deceleration start flag" is stored into t he following buffer memory addresses.

Buffer memory address
Monitor item Monitor
value Storage details Axis
1Axis
2Axis
3Axis
4
Md.48 Deceleration start
flag
0: Status other than below
1: Status from deceleration start to next
operation start or manual pulse generator
operation enable
899 999 1099 1199
Refer to Section 5.6 "List of monitor data" for information on the storage details.