Mitsubishi Electronics QD75P, QD75D Operation when JOG start signal is turned on in test mode

Models: QD75P QD75D

1 768
Download 768 pages 34.72 Kb
Page 466
Image 466

11 MANUAL CONTROL

MELSEC-Q

When "JOG start signal" is turned ON when peripheral devices are in the test mode:

If "JOG star signal" is turned ON when peripheral devices are in the test mode, the "JOG start signal" will be ignored and inching operation will not be carried out.

 

Inching operation not

Forward run inching

 

possible because JOG

Inching operation not possible

operation executed

start signal does not rise

 

because the operation is in the

 

 

test mode.

 

 

 

 

t

ON

 

 

In test mode

OFF

 

 

 

Forward run JOG start signal [Y8,YA,YC,YE] OFF

ON

Fig. 11.16 Operation when JOG start signal is turned ON in test mode

When "JOG start signal" is turned ON immediately after stop signal OFF (within 100 ms):

If "JOG start signal" is turned ON immediately after the stop signal is turned OFF (within 100 ms), the "JOG start signal" will be ignored and inching operation will not be carried out.

Forward run inching operation

ON

Forward run JOG start signal [Y8,YA,YC,YE]

ON

Axis stop signal OFF [Y4,Y5,Y6,Y7]

OFF

100ms

A rise of JOG start signal is ignored.

Fig. 11.17 Operation when JOG start signal is turned ON immediately after stop signal is turned OFF

11 - 26

Page 466
Image 466
Mitsubishi Electronics QD75P, QD75D user manual Operation when JOG start signal is turned on in test mode