5 DATA USED FOR POSITIONING CONTROL

MELSEC-Q

Storage item

Storage details

This area stores the states (ON/OFF) of various flags.

 

 

Information on the following flags is stored.

 

 

In speed control flag:

 

 

This signal that comes ON under the speed control can be used to judge whether the

 

 

operation is performed under the speed control or position control. The signal goes OFF

 

 

when the power is switched ON, under the position control, and during JOG operation or

 

 

manual pulse generator operation. During the speed-position or position-speed switching

 

 

control, this signal comes ON only when the speed control is in effect. During the speed-

 

 

position switching control, this signal goes OFF when the speed-position switching signal

 

 

executes a switching over from speed control to position control. During the position-

 

 

speed switching control, this signal comes ON when the position-speed switching signal

 

 

executes a switching over from position control to speed control.

 

 

Speed-position switching latch flag:

 

 

This signal is used during the speed-position switching control (INC mode) for interlocking

 

 

the movement amount change function. During the speed-position switching control (INC

 

 

mode), this signal comes ON when position control takes over. This signal goes OFF

 

 

when the next positioning data is processed, and during JOG operation or manual pulse

 

 

generator operation.

 

 

Command in-position flag:

 

 

This signal is ON when the remaining distance is equal to or less than the command in-

 

 

position range (set by a detailed parameter). This signal remains OFF with data that

 

 

specify the continuous path control (P11) as the operation pattern. The state of this signal

 

Status

is monitored every 1.8 ms except when the monitoring is canceled under the speed control

Md.31

or while the speed control is in effect during the speed-position or position-speed switching

 

 

control. While operations are performed with interpolation, this signal comes ON only in

 

 

respect of the starting axis. (This signal goes OFF in respect of all axes upon starting.)

 

 

OPR request flag:

 

 

This signal comes ON when the power is switched ON, when the drive unit READY signal

 

 

goes OFF, when the PLC READY signal goes ON, when a machine OPR operation

 

 

starts. This signal goes OFF when a machine OPR operation completes.

 

 

OPR complete flag:

 

 

This signal comes ON when a machine OPR operation completes normally. This signal

 

 

goes OFF when the operation starts and when the drive unit READY signal goes OFF.

 

 

Position-speed switching latch flag:

 

 

This signal is used during the position-speed switching control for interlocking the

 

 

command speed change function. During the position-speed switching control, this signal

 

 

comes ON when speed control takes over. This signal goes OFF when the next

 

 

positioning data is processed, and during JOG operation or manual pulse generator

 

 

operation.

 

 

Axis warning detection flag:

 

 

This signal comes On when an axis warning is reported and goes OFF when the axis error

 

 

reset signal comes ON.

 

 

Speed change 0 flag:

 

 

This signal comes ON when a speed change request that specifies 0 as the new speed

 

 

value is issued. This signal comes ON when a speed change request that specifies a new

 

 

speed value other than 0 is issued.

 

 

This area stores the target value (

Da.6

Positioning address/movement amount)

 

 

for a positioning operation.

 

 

 

 

Target value

 

 

 

 

 

 

Md.32

At the beginning of positioning control: Stores the value of "

Da.6

Positioning

 

 

 

 

 

 

 

address/movement amount".

 

 

At other times

: Stores "0".

5 - 102