9 MAJOR POSITIONING CONTROL

MELSEC-Q

(4)If the value set in " Da.6 Positioning address/movement amount" is outside the software stroke limit ( Pr.12 , Pr.13 ) setting range, an error "Software

stroke limit +, – (error code: 507 or 508)" will occur at the positioning start, and the operation will not start.

(5)An error (error code: 507 or 508) will occur if the new current value is outside the software stroke limit range.

Positioning data setting examples

The following table shows the setting examples when " current value changing" is set in the positioning data No. 1 of axis 1.

 

Setting item

 

Setting example

Setting details

 

 

 

 

Set "Positioning complete" assuming that

 

Da.1

Operation

Positioning complete

the next positioning data will be executed.

 

pattern

("Continuous path control" cannot be set by

 

 

 

 

 

 

 

current value change.)

 

Da.2

Control

Current value changing

Set the current value changing.

 

system

 

 

 

 

 

 

 

Da.3

Acceleration

Setting not required (Setting value is

 

time No.

ignored.)

 

 

 

 

Da.4

Deceleration

Setting not required (Setting value is

 

time No.

ignored.)

 

 

 

 

Da.5

Axis to be

Setting not required (Setting value is

Axis 1

interpolated

ignored.)

 

 

positioning

 

Positioning

 

Set the address to which address change is

data No. 1

 

address/

 

 

 

desired. (Assuming that the "

 

Unit

Da.6

10000.0 m

Pr.1

 

movement

 

 

 

setting" is set to "mm".)

 

 

amount

 

 

 

 

 

 

 

 

Da.7

Arc address

Setting not required (Setting value is

 

ignored.)

 

 

 

 

 

Da.8

Command

Setting not required (Setting value is

 

speed

ignored.)

 

 

 

 

Da.9

Dwell time

Setting not required (Setting value is

 

ignored.)

 

 

 

 

 

 

 

 

Set this when other sub operation

 

Da.10

M code

10

commands are issued in combination with

 

 

 

 

the No. 1 positioning data.

Refer to Section 5.3 "List of positioning data" for information on the setting details.

9 - 106

Page 406
Image 406