9 - 38
MELSEC-Q
9 MAJOR POSITIONING CONTROL
POINTS
(1) When the "reference axis speed" is set dur ing 3-axis linear intrpolation control,
set so the major axis side becomes the referenc e axis. If the minor axis side is
set as the reference axis, the major axis side s peed may exceed the " Pr.8
Speed limit value".
(2) Refer to Section 9.1.6 "Interpolation contr ol" for the reference axis and
interpolation axis combinations.