12CONTROL SUB FUNCTIONS

12.7 Other functions

MELSEC-Q

Other functions include the "step function", "skip function", "M code output function", "teaching function", "target position change function", "command in-position function", "acceleration/deceleration processing function", "pre-reading start function", "deceleration start flag function" and "stop command processing for deceleration stop function". Each function is executed by parameter setting or sequence program creation and writing.

12.7.1 Step function

The "step function" is used to confirm each operation of the positioning control one by one.

It is used in debugging work for major positioning control, etc.

A positioning operation in which a "step function" is used is called a "step operation". In step operations, the timing for stopping the control can be set. (This is called the "step mode".) Control stopped by a step operation can be continued by setting "step continue" (to continue the control)" or restarted by setting "restart" in the "step start information".

The details shown below explain about the "step function".

[1]Relation between the step function and various controls

[2]Step mode

[3]Step start information

[4]Using the step operation

[5]Control details

[6]Precautions during control

[7]Step function settings

[1]Relation between the step function and various controls

The following table shows the relation between the "step function" and various controls.

 

 

Control type

Step function

Step applicability

OPR control

Machine OPR control

 

Step operation not possible

Fast OPR control

 

 

 

1-axis linear control

 

 

 

 

 

2 to 4-axes linear interpolation control

 

 

 

 

Position

1-axis fixed-feed control

 

Step operation possible

 

 

control

2 to 4- axes fixed-feed control

 

 

 

 

 

 

Major

 

(interpolation)

 

 

 

 

2-axis circular interpolation control

 

 

 

positioning

 

 

 

 

1 to 4- axes Speed control

 

Step operation not possible

control

 

Speed-position switching control

 

 

 

 

 

 

 

 

Position-speed switching control

 

Step operation possible

 

Other

Current value changing

 

 

 

 

JUMP instruction, NOP instruction,

 

 

 

 

control

 

Step operation not possible

 

 

LOOP to LEND

 

 

 

Manual

JOG operation, Inching operation

 

Step operation not possible

 

control

Manual pulse generator operation

 

 

 

 

 

: Set when required. : Setting not possible

12 - 58

Page 534