3SPECIFICATIONS AND FUNCTIONS

Important

MELSEC-Q

1: The BUSY signal turns ON even when position control of movement amount 0 is executed. However, since the ON time is short, the ON status may not be detected in the sequence program.

2: "Positioning complete" of the QD75 refers to the point when the pulse output from QD75 is completed.

Thus, even if the QD75's positioning complete signal turns ON, the system may continue operation.

3.3.3 Detail of output signals (PLC CPU QD75)

The ON/OFF timing and conditions of the output signals are shown below.

Device No.

 

Signal name

 

 

 

 

 

 

Details

Y0

PLC READY

OFF:

(a) This signal notifies the QD75 that the PLC CPU is normal.

 

 

 

PLC READY OFF

 

• It is turned ON/OFF with the sequence program.

 

 

 

ON:

 

• The PLC READY signal is turned ON during positioning

 

 

 

PLC READY ON

 

control, OPR control, JOG operation, inching operation, and

 

 

 

 

 

manual pulse generator operation, unless the system is in the

 

 

 

 

 

peripheral device test mode.

 

 

 

 

(b) When parameters are changed, the PLC READY signal is turned

 

 

 

 

OFF depending on the parameter (Refer to Chapter 7.).

 

 

 

 

(c) The following processes are carried out when the PLC READY

 

 

 

 

signal turns from OFF to ON.

 

 

 

 

 

• The parameter setting range is checked.

 

 

 

 

 

• The QD75 READY signal [X0] turns ON.

 

 

 

 

(d) The following processes are carried out when the PLC READY

 

 

 

 

signal turns from ON to OFF.

 

 

 

 

In these cases, the OFF time should be set to 100ms or more.

 

 

 

 

 

• The QD75 READY signal [X0] turns OFF.

 

 

 

 

 

• The operating axis stops.

 

 

 

 

 

• The M code ON signal [X4 to X7] for each axis turns OFF, and

 

 

 

 

 

"0" is stored in "

 

Valid M code".

 

 

 

 

Md.25

 

 

 

 

(e) When parameters or positioning data (No. 1 to 600) are written

 

 

 

 

from the peripheral device or PLC CPU to the flash ROM, the

 

 

 

 

PLC READY signal will turn OFF.

Y4

Axis 1

Axis stop

OFF:

• When the axis stop signal turns ON, the OPR control, positioning

Y5

Axis 2

 

Axis stop not

control, JOG operation, inching operation and manual pulse

Y6

Axis 3

 

requested

generator operation will stop.

Y7

Axis 4

 

ON:

• By turning the axis stop signal ON during positioning operation, the

 

 

 

Axis stop requested

positioning operation will be "stopped".

 

 

 

 

• Whether to decelerate or suddenly stop can be selected with

 

 

 

 

"

 

Stop group 3 sudden stop selection".

 

 

 

 

Pr.39

 

 

 

 

• During interpolation control of the positioning operation, if the axis

 

 

 

 

stop signal of any axis turns ON, all axes in the interpolation

 

 

 

 

control will decelerate and stop.

Y8

Axis 1

Forward run JOG start

OFF:

• When the JOG start signal is ON, JOG operation will be carried

Y9

Axis 1

Reverse run JOG start

JOG not started

 

 

 

 

 

 

 

out at the "

Cd.17

JOG speed". When the JOG start signal turns

YA

Axis 2

Forward run JOG start

ON:

OFF, the operation will decelerate and stop.

YB

Axis 2

Reverse run JOG start

JOG started

• When inching movement amount is set, the designated movement

YC

Axis 3

Forward run JOG start

 

 

amount is output for one control cycle and then the operation

YD

Axis 3

Reverse run JOG start

 

 

stops.

YE

Axis 4

Forward run JOG start

 

 

 

 

 

 

 

 

 

YF

Axis 4

Reverse run JOG start

 

 

 

 

 

 

 

 

Y10

Axis 1

Positioning start

OFF:

• OPR operation or positioning operation is started.

Y11

Axis 2

 

Positioning start not

• The positioning start signal is valid at the rising edge, and the

Y12

Axis 3

 

requested

operation is started.

Y13

Axis 4

 

ON:

• When the positioning start signal turns ON during BUSY, the

 

 

 

Positioning start

operation starting warning will occur (warning code: 100).

 

 

 

requested

 

 

 

 

 

 

 

Y14

Axis 1

Execution prohibition

OFF:

• If the execution prohibition flag is ON when the positioning start

Y15

Axis 2

flag

Not during execution

signal turns ON, positioning control does not start until the

Y16

Axis 3

 

prohibition

execution prohibition flag turns OFF. (Pulse output not provided)

Y17

Axis 4

 

ON:

Used with the "Pre-reading start function". (Refer to Section

 

 

 

During execution

12.7.8)

 

 

 

 

 

 

 

 

prohibition

 

 

 

 

 

 

 

3 - 16

Page 64
Image 64
Mitsubishi Electronics QD75P, QD75D user manual Detail of output signals PLC CPU QD75