5DATA USED FOR POSITIONING CONTROL

5.1.3 Setting items for OPR parameters

MELSEC-Q

When carrying out "OPR control", the "OPR parameters" must be set. The setting items for the "OPR parameters" are shown below.

The "OPR parameters" are set commonly for each axis.

Refer to Chapter 8 "OPR control" for details on the "OPR control", and to Section 5.2 "List of parameters" for details on each setting item.

 

 

OPR control

 

 

 

 

 

Fast

 

 

 

 

 

Machine OPR control

 

 

 

 

 

 

 

OPR control

OPR parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

parameters

Pr.43

OPR method

Near-point dog method

Stopper method 1)

Stopper method 2)

Stopper method 3)

Count method 1)

Count method 2)

Pr.44

OPR direction

basic

Pr.45

OP address

 

 

 

 

 

 

OPR

Pr.46

OPR speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pr.47

Creep speed

 

 

 

 

 

 

 

Pr.48

OPR retry

R

R

R

R

R

 

Pr.49

OPR dwell time

 

 

Pr.50

Setting for the movement amount after near-

 

 

parameters

 

point dog ON

 

 

 

 

 

 

Pr.51

OPR acceleration time selection

 

 

 

 

 

 

Pr.52

OPR deceleration time selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

detailed

Pr.53

OP shift amount

S

S

S

S

S

S

Pr.54

OPR torque limit value

 

 

 

 

 

 

 

 

 

 

 

OPR

Pr.55

Deviation counter clear signal output time

C

C

C

C

C

 

 

 

 

 

 

 

 

 

Pr.56

Speed designation during OP shift

S

S

S

S

S

S

 

Pr.57

Dwell time during OPR retry

R

R

R

R

R

: Always set

: Preset parameters are used for machine OPR control.

: Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or within the setting range, there is no problem.)

R: Set when using the "12.2.1 OPR retry function". ("–" when not set.)

S: Set when using the "12.2.2 OP shift function". ("–" when not set.)

C: Set the deviation counter clear signal output time. (Read as "–" when the setting is not required.)

Checking the OPR parameters.

Pr.43

to

Pr.57

are checked with the following timing.

(1)When the "PLC READY signal [Y0]" output from the PLC CPU to the QD75 changes from OFF to ON

(2)When the test operation button is turned ON in the test mode using GX Configurator-QP

(3)When an error check is carried out with GX Configurator-QP

5 - 6

Page 94
Image 94
Mitsubishi Electronics QD75P, QD75D user manual Setting items for OPR parameters, Checking the OPR parameters, Pr.43 Pr.57