12 CONTROL SUB FUNCTIONS

MELSEC-Q

(2)OP shift operation at the " Pr.47 Creep speed"

(When " Pr.56 Speed designation during OP shift" is 1)

Pr. 44 OPR direction

Pr. 47 Creep

When the " Pr. 53 OP

speed

shift amount" is positive

Zero point

 

 

OP

Machine OPR start

 

 

 

 

 

When the " Pr. 53 OP

Near-point dog

 

 

 

 

shift amount" is negative

 

 

 

 

 

 

 

 

Zero signal

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 12.7 OP shift operation at the creep speed

[4] Precautions during control

The following data are set after the OP shift amount is complete.

OPR complete flag ("

Md.31

Status: b4)

Md.20

Current feed value

Md.21

Md.26

Md.34

Machine feed value

Axis operation status

Movement amount after near-point dog ON ("

Pr.53

OP shift

amount" is not added.)

OPR request flag ( Md.31 shift.

Status: b3) is reset after completion of the OP

[5] Setting the OP shift function

To use the "OP shift function", set the required details in the parameters shown in the following table, and write them to the QD75.

When the parameters are set, the OP shift function will be added to the machine OPR control. The set details are validated at the rising edge (OFF ON) of the PLC READY signal (Y0).

 

 

Setting item

Setting

 

 

Setting details

Factory-set

 

 

value

 

 

initial value

 

 

 

 

 

 

 

 

 

 

OP shift amount

 

Set the shift amount during the OP shift.

0

 

Pr.53

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

Select the speed during the OP shift

 

 

 

 

 

0:

 

OPR speed

 

 

Pr.56

 

designation

 

Pr.46

0

 

 

 

 

 

 

 

 

 

during OP shift

 

1:

 

Creep speed

 

 

 

 

Pr.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to Section 5.2 "List of parameters" for setting details.

REMARK

Parameters are set for each axis.

It is recommended that the parameters be set whenever possible with GX Configurator-QP. Execution by sequence program uses many sequence programs and devices. The execution becomes complicated, and the scan times will increase.