10 HIGH-LEVEL POSITIONING CONTROL

MELSEC-Q

Set in QD75 the " block start data" and "condition data" corresponding to the following "block Nos. 7001 to 7004" using GX Configurator-QP or the sequence program. (The following drawing shows an example for axis 1.)

50th point

2nd point

Setting item

Buffer memory address

50th point

2nd point

Setting item

Buffer memory address

1st point

 

 

 

 

 

 

Setting item

data

b15

 

b8 b7

b0

 

 

 

 

start

 

 

Da12

Positioning data No.

 

Da11 Shape

 

1 block

 

 

b15

 

b8 b7

b0

Axis

 

 

 

 

 

 

 

Da13

Special start

Da14 Parameter

 

 

 

instruction

 

Buffer memory address

26200

26250

Buffer memory address

26201

26251

26249

26299

1st point

 

 

 

 

 

Setting item

 

data

b15

b8 b7

 

b0

 

 

 

 

start

 

Da12 Positioning data No.

 

Da11 Shape

 

 

1 block

 

 

 

b15

b8 b7

 

b0

Axis

 

 

 

 

 

 

 

Da13 Special start

Da14

Parameter

 

 

instruction

 

 

Buffer memory address

26800

26850

Buffer memory address

26801

26851

26849

26899

 

 

 

 

 

No.10

 

 

 

 

 

 

Setting item

 

 

No.2

 

 

Condition identifier

 

 

No.1

 

 

 

 

Buffer memory

 

 

Setting item

Buffer memory address

 

 

address

 

 

 

 

 

 

 

data

Condition identifier

 

 

 

26310

b15

b12 b11

b8 b7

 

b0

 

 

 

 

26300

 

condition

 

 

 

 

 

Da16

Condition

 

Da15 Condition target

26311

operater

 

 

 

Open

 

26301

26312

Da17

Address

 

 

26302

26313

 

 

26314

1

 

 

 

 

26303

26315

Axis

Da18

Parameter 1

 

26304

 

26316

 

 

 

 

26305

 

 

 

 

26317

Da19

Parameter 2

 

26306

 

26318

 

 

 

 

 

26307

 

 

 

 

 

26319

Open

26308

26309

 

Buffer memory address

26390

26391

26392

26393

26394

26395

26396

26397

26398

26399

 

 

 

 

 

No.10

 

 

 

 

 

 

Setting item

 

 

No.2

 

 

Condition identifier

 

 

No.1

 

 

 

 

Buffer memory

 

 

Setting item

Buffer memory address

 

 

address

 

 

 

 

 

 

 

data

Condition identifier

 

 

 

26910

b15

b12 b11

b8 b7

 

b0

 

 

 

 

26900

 

condition

 

 

 

 

 

Da16

Condition

 

Da15 Condition target

26911

operater

 

 

 

Open

 

26901

26912

Da17

Address

 

 

26902

26913

 

 

26914

1

 

 

 

 

26903

26915

Axis

Da18

Parameter 1

 

26904

 

26916

 

 

 

 

26905

 

 

 

 

26917

Da19

Parameter 2

 

26906

 

26918

 

 

 

 

 

26907

 

 

 

 

 

26919

Open

26908

26909

 

Buffer memory address

26990

26991

26992

26993

26994

26995

26996

26997

26998

26999

7001

7004

10 - 5

Page 419