5 DATA USED FOR POSITIONING CONTROL

MELSEC-Q

 

Default

Storage buffer

Setting value

memory address

value

 

Axis 1 Axis 2 Axis 3 Axis 4

 

 

Set with a decimal.

Setting value K 1

OPR request flag OFF request

0

1521

1621

1721

1821

1: Turns the "OPR request flag"

 

 

 

 

 

from ON to OFF.

 

 

 

 

 

The QD75 resets the value to "0" automatically when the OPR request flag is turned OFF.

(This indicates the completion of OPR request flag OFF request.)

Set with a decimal.

Setting value

K

 

1522

1622

1722

1822

 

 

1

 

 

1523

1623

1723

1823

 

Manul pulse generator

 

 

 

 

 

 

 

 

1 pulse input

 

 

 

 

 

 

magnification

 

 

 

 

 

 

1 to 100

 

 

 

 

 

Set with a decimal.

Setting value

K

0

1524 1624 1724 1824

Manual pulse generator enable flag

0:Disable manual pulse generator operation.

1:Enable manual pulse generator operation.

Set with a decimal.

Setting value

K

Torque change value

0

1525 1625 1725 1825

 

1 to Pr.17 Torque limit setting value

 

 

5 - 123

Page 211
Image 211
Mitsubishi Electronics QD75D 1521 1621 1721 1821, 1522 1622 1722 1822 1523 1623 1723 1823, 1524 1624 1724, 1525 1625 1725