5DATA USED FOR POSITIONING CONTROL

Da.11 Shape

MELSEC-Q

 

 

Set whether to carry out only the local "block start data" and then end control, or to

 

 

execute the "block start data" set in the next point.

 

 

 

 

Setting value

Setting details

0

: End

Execute the designated point's "block start data", and then complete the control.

1

: Continue

Execute the designated point's "block start data", and after completing control, execute the next

point's "block start data".

 

 

 

 

 

Da.12

Start data No.

Set the "positioning data No." designated with the "block start data".

Da.13

Special start instruction

 

Set the "special start instruction " for using "high-level positioning control". (Set

 

how to start the positioning data set in "

 

Start data No.".)

 

Da.12

 

 

Setting value

Setting details

00H : Block start

Execute the random block positioning data in the set order with one start.

(Normal start)

 

 

 

 

Carry out the condition judgment set in "condition data" for the designated positioning data, and

01H : Condition start

when the conditions are established, execute the "block start data". If not established, ignore

 

that "block start data", and then execute the next point's "block start data".

 

 

 

Carry out the condition judgment set in "condition data" for the designated positioning data, and

02H : Wait start

when the conditions are established, execute the "block start data". If not established, stop the

 

control (wait) until the conditions are established.

03H : Simultaneous

Simultaneous execute (output pulses at same timing) the positioning data with the No.

designated for the axis designated in the "condition data".

start

Up to four axes can start simultaneously.

 

 

 

04H : Repeated start

Repeat the program from the block start data with the "FOR loop" to the block start data with

(FOR loop)

"NEXT" for the designated No. of times.

05H : Repeated start

Repeat the program from the block start data with the "FOR condition" to the block start data

(FOR condition)

with "NEXT" until the conditions set in the "condition data" are established.

 

 

06H : NEXT start

Set the end of the repetition when "05H: Repetition start (FOR loop)" or "06H: Repetition start

(FOR condition)" is set.

 

 

Refer to Chapter 10 "High-level Positioning Control" for details on the control.

5 - 78