12 - 31
MELSEC-Q
12 CONTROL SUB FUNCTIONS
[7] Setting when the control unit is "degree"

Current value address

The " Md.20 Current feed value" address is a ring address between 0 and
359.99999°.
0° 0° 0°
359.99999° 359.99999°
Fig. 12.17 Current value address when the contr ol unit is "degree".

Setting the software stroke limit

The upper limit value/lower limit value of the software strok e limit is a value
between 0 and 359.99999°.
(1) Setting when the software stroke limit is to be validated.
When the software stroke limit is to be validated, set the upper lim it value in a
clockwise direction from the lower limit value.
Section A
315º Set in a clockwise direction
Upper limit
Lower limit
90º
Section B
(a) Set the movement range of section A as follows.
Software stroke limit lower limit value ................ 315.00000°.
Software stroke limit upper limit value ................ 90.00000°.
(b) Set the movement range of section B as follows.
Software stroke limit lower limit value ................ 90.00000°.
Software stroke limit upper limit value ................ 315.00000°.
Fig. 12.18 Software stroke limit when the control unit is " deg ree "