12 CONTROL SUB FUNCTIONS

MELSEC-Q

[7] Setting when the control unit is "degree"

Current value address

The " Md.20

359.99999°

Current feed value" address is a ring address between 0 and

.

359.99999° 359.99999°

0° 0° 0°

Fig. 12.17 Current value address when the control unit is "degree".

Setting the software stroke limit

The upper limit value/lower limit value of the software stroke limit is a value between 0 and 359.99999° .

(1)Setting when the software stroke limit is to be validated.

When the software stroke limit is to be validated, set the upper limit value in a clockwise direction from the lower limit value.

Lower limit

 

315º

Set in a clockwise direction

 

Section A

Section B

Upper limit 90º

(a)Set the movement range of section A as follows.

Software stroke limit lower limit value ................ 315.00000°.

Software stroke limit upper limit value................ 90.00000°.

(b)Set the movement range of section B as follows.

Software stroke limit lower limit value ................ 90.00000°.

Software stroke limit upper limit value................ 315.00000°.

Fig. 12.18 Software stroke limit when the control unit is "degree"

12 - 31

Page 507
Image 507