APPENDICES

MELSEC-Q

Items of A1SD75

Buffer memory address

A1SD75

QD75

Common for axis 1, 2, 3

Common for axis 1, 2, 3, 4

 

 

 

 

 

 

 

 

 

 

 

 

Md.1

In test mode flag

 

450

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

Md.2

Module name

 

451

 

 

 

 

 

 

 

 

 

452 453

 

 

 

Md.3

 

OS type

 

 

 

 

 

454 455

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

456

 

 

 

Md.4

 

OS version

 

 

 

 

 

457

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.5

Clock data (hour: minute)

 

460

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.6

Clock data (second: 100 ms)

 

461

 

(Pointer number)

 

 

(0) to (15)

 

Md.7

 

Start axis

 

462 to 537

 

1212 to 1287

 

 

 

 

 

 

 

 

 

(QD75:

Md. 3

Start information)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.8

Operation type

 

463 to 538

 

1213 to 1288

 

 

 

 

 

 

 

 

 

(QD75:

Md. 4

Start No.)

 

 

 

 

 

 

 

 

 

 

 

Start

 

 

 

 

Md.9

Start Hour: minute

464 to 539

 

1214 to 1289

 

 

 

 

 

 

 

history

 

(QD75:

Md. 5

Start Hour)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.10

 

Start Second: 100 ms

 

465 to 540

 

1215 to 1290

 

 

 

 

 

 

 

 

 

(QD75:

Md. 6

Start Minute: second)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.11

 

Error judgment

 

466 to 541

 

1216 to 1291

 

 

 

 

 

 

 

 

 

 

 

 

Md.12

 

Start history pointer

 

542

 

1292

(Pointer number)

 

(0) to (15)

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.13

 

Start axis

 

543 to 618

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.14

 

Operation type

Start

544 to 619

 

 

 

 

 

 

 

 

 

 

 

 

 

history

 

 

 

 

Md.15

 

Start Hour: minute

545 to 620

 

 

 

 

 

 

 

 

during

 

 

 

 

Md.16

 

Start Second: 100 ms

errors

546 to 621

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.17

 

Error judgment

 

547 to 622

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.18

 

Start history storage during error

 

623

 

(Pointer number)

 

 

(0) to (15)

 

 

 

 

 

 

 

 

 

 

 

 

Md.19

 

Axis in which the error occurred

 

624 to 684

 

1293 to 1353

 

 

 

 

 

 

 

 

 

 

 

 

Md.20

 

Axis error No.

 

625 to 685

 

1294 to 1354

 

 

 

 

 

 

 

 

 

 

 

 

Md.21

 

Axis error occurrence Hour: minute

 

626 to 686

 

1295 to 1355

 

 

 

 

 

 

 

Error

 

(QD75:

Md. 11

Axis error occurrence (Hour))

 

 

 

 

 

 

 

 

 

 

history

 

 

 

 

Md.22

 

Axis error occurrence Second:

 

 

 

 

 

 

 

 

 

 

 

 

 

100 ms

 

627 to 687

 

1296 to 1356

(QD75:

Md. 12

Axis error occurrence

 

 

 

 

(Minute: second))

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.23

 

Error history pointer

 

688

 

1357

 

 

 

 

 

 

 

 

 

 

 

Appendix - 54

Page 696
Image 696
Mitsubishi Electronics QD75P Items of A1SD75 Buffer memory address QD75, Test mode flag 450, Module name 451 452, OS type