9 MAJOR POSITIONING CONTROL

MELSEC-Q

Positioning data setting examples

The following table shows setting examples when "speed-position switching control (ABS mode) by forward run" is set in positioning data No. 1 of axis 1.

Setting item

Da.1 Operation pattern

Control system

Da.3 Acceleration time No.

No. 1

Da.4

Deceleration time No.

data

 

Axis to be

Positioning

Da.5

 

interpolated

 

 

 

 

Positioning address/

Axis 1

 

movement amount

 

Arc address

 

 

Setting example

 

Setting details

Positioning

Set "Positioning complete" assuming the next positioning data will not

be executed. ("Continuous path control" cannot be set in "speed-

complete

position switching control (ABS mode)".)

 

Forward run:

Set speed-position switching control by forward run.

speed/position

 

Designate the value set in "

 

Acceleration time 1" as the

1

Pr.25

acceleration time at start.

 

 

 

 

 

 

Designate the value set in "

 

Deceleration time 0" as the

0

Pr.10

deceleration time at deceleration.

 

Setting not required. (Setting value is ignored.)

 

ABS mode ( Pr.150 = 2)

270.00000

Set the address after the switching to position control. (Assuming that

degree

the "

 

Unit setting" is set to "mm".)

 

Pr.1

Setting not required. (Setting value is ignored.)

 

Da.8

Command speed

6000.00mm/min Set the speed to be controlled.

 

 

 

 

 

 

Da.9

 

 

Set a time from the positioning stop (pulse output stop) by position

 

Dwell time

500ms

control until the positioning complete signal is output. When the

 

 

 

 

system is stopped by speed control, ignore the setting value.

 

 

 

 

 

 

 

M code

10

Set this when other sub operation commands are issued in

 

 

combination with the No. 1 positioning data.

 

 

 

 

Refer to Section 5.3 "List of positioning data" for information on the setting details.

9 - 97