9MAJOR POSITIONING CONTROL

Restrictions

MELSEC-Q

(1)A 1.8ms error will occur in the current value update timing when the stored "current feed value" is used in the control.

A 56.8ms error will occur in the current value update timing when the stored "machine feed value" is used in the control.

(2)The "current feed value" and "machine feed value" may differ from the values

set in "

Da.6

Positioning address/movement amount" of the positioning data if

the movement amount per pulse is not set to "1".

Monitoring the current value

The "current feed value" and "machine feed value" are stored in the following buffer memory addresses, and can be read using a "DFRO (P) command" from the PLC CPU.

 

 

 

 

Buffer memory addresses

 

 

 

 

Axis 1

Axis 2

Axis 3

Axis 4

 

 

 

 

 

 

 

 

Md.20

Current feed value

800, 801

900, 900

1000, 1001

1100, 1101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Md.21

Machine feed value

802, 803

902, 903

1002, 1003

1102, 1103

 

 

 

 

 

 

 

Example

Program in which the axis 1 current feed value is read to D104 and D105

<Read current feed value to D104 and D105>

9 - 17

Page 317
Image 317