5 DATA USED FOR POSITIONING CONTROL

MELSEC-Q

5.7.2 Axis control data

 

 

Setting item

 

 

 

Setting details

 

 

 

 

 

 

 

 

 

 

 

 

Set the positioning start No.

 

 

Cd.3

Positioning start No.

 

(Only 1 to 600 for the Pre-reading start function. For details, refer to Section

 

 

 

 

 

12.7.8 "Pre-reading start function".)

 

 

 

 

 

 

 

 

 

 

 

 

Set a " starting point No." (1 to 50) if block start data is used for positioning.

 

 

Cd.4

Positioning starting point No.

 

 

(Handled as "1" if the value of other than 1 to 50 is set.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clears the axis error detection, axis error No., axis warning detection and axis

 

 

 

 

 

warning No.

 

 

Cd.5

Axis error reset

 

When the QD75 axis operation state is "in error occurrence", the error is cleared

 

 

 

 

 

 

 

 

 

and the QD75 is returned to the "waiting" state.

 

 

 

 

 

 

 

 

 

 

When positioning is stopped for any reason (when axis operation state is

 

 

 

 

 

 

 

 

 

 

Cd.6

Restart command

 

"stopped"), set "1" in

Cd.6

. Positioning will be carried out again from the stopped

 

 

 

 

 

position to the end point of the stopped positioning data.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cd.7

M code OFF request

The M code ON signal turns OFF.

 

 

 

 

 

 

 

 

 

5 - 112

Page 200
Image 200
Mitsubishi Electronics QD75P, QD75D user manual Axis control data, Setting item Setting details Set the positioning start No