APPENDICES

MELSEC-Q

Functions deleted from those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

Deleted functions

Remarks

Stepping motor mode

OPR operation error (Error code: 208)

Fast machine OPR

Special start (stop)

 

In the QD75, the start block area on the buffer memory is

Indirect designation

expanded to five blocks (0 to 4). Each start block can be directly

 

designated with positioning start No. (7000 to 7004).

Block transfer

With the A1SD75, this interface is used to set positioning data

 

Nos. 101 to 600 that do not exist on the buffer memory.

Positioning data I/F

Since all positioning data can be set in the buffer memory with the

 

QD75, this function is deleted.

Start history storage during error

The contents are the same as those of the start history. Therefore,

the QD75 stores only the start history.

 

 

These data were deleted because they can be displayed in system

System monitor data (module type, OS information)

monitor "Module's detailed information" of GX Developer.

 

(Refer to GX Developer Operating Manual.)

Functions changed from those of A1SD75P1-S3/A1SD75P2-S3/A1SD75P3-S3

Changed functions

 

 

 

 

 

Descriptions

 

1.

The limit check of arc address is carried out only when a sub

 

 

point is designated. It is not carried out when a center point is

 

 

designated.

 

2.

The software stroke limit check during speed control is carried

 

 

out in the following cases:

 

 

• When the software stroke limit is applied to the current feed

 

 

value with

 

and the current feed value is updated with

 

 

Pr.14

 

 

 

 

.

 

 

 

Pr.21

 

 

• When the software stroke limit is applied to the machine feed

Software stroke limit function

 

value.

 

3.

If an attempt is made to change the current value but the

 

 

designated address is out of the software stroke limit range, the

 

 

attempt is considered as an error and the current value is not

 

 

changed.

 

4.

The conventional models feature three types of software stroke

 

 

limit error codes for upper limit and lower limit respectively. With

 

 

the QD75, errors for the software stroke upper limit are

 

 

integrated into error code 507, and errors for the lower limit are

 

 

integrated into error code 508. Error codes 509 to 512 are

 

 

deleted.

 

1.

An error occurs when the designated new current value is out of

Current value changing

 

the software stroke limit range.

M code function

2. The M code setting value is valid during the positioning data

 

 

current value changing instruction.

 

1.

An error occurs when the command frequency value calculated

 

 

from the speed limit value is out of the maximum command

Acceleration/deceleration control

 

frequency of the positioning module being used.

2.

Only two-word type (1 to 8388608ms) can be used as the

 

 

 

setting value for the acceleration/deceleration time. (The switch

 

 

between 1-word type and 2-word type is eliminated.)

Appendix - 48