5 - 42
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting value, setting range Setting value buffer memory
address
Item Value set with peripheral device Value set with sequence
program
Default
value Axis 1 Axis 2 Axis 3 Axis 4
Pr.40
Positioning complete signal
output time
0 to 65535 (ms)
0 to 65535 (ms)
0 to 32767 :
Set as a decimal
32768 to 65535:
Convert into hexadecimal
and set
300 59 209 359 509
Pr.41
Allowable circular
interpolation error width
The setting value range differs depending on the " Pr.1 Unit
setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
100 60
61 210
211 360
361 510
511
0: External positioning start 0
1: External speed change
request 1
2: Speed-position, position-
speed switching request 2
Pr.42
External command function
selection
3: Skip request 3
0 62 212 362 512
Pr.40 Positioning complete signal output time
Set the output time of the positioning complete signal [X14, X15, X16, X 17] outputfrom the QD75.A positioning completes when the specified dwell time has pass ed after the QD75had terminated the output.
M
QD75
[Y10, Y11, Y12, Y13]
PLC
PLC CPUPositioning start signal
Positioning
complete signal
[X14, X15, X16, X17]
Positioning
Positioning
start signal
Start complete
signal
BUSY signal
Positioning
complete signal
Positioning complete signal
(after dwell time has passed)
Output time
Positioning complete signal output time