APPENDICES

 

 

 

 

 

 

MELSEC-Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changed functions

 

 

 

Descriptions

 

 

 

 

 

 

 

 

No. 9004 (Multiple axes simultaneous start control) is added.

 

Positioning start No.

Nos. 7004 to 7010 (block start designation) and 8000 to 8049 (indirect

 

 

 

 

 

 

designation) are deleted.

 

 

 

Block start data

With the QD75, the number of blocks is changed to 5 (7000 to 7004). (With the

 

A1SD75, this data is called "positioning start information".)

 

 

 

 

 

 

 

Special start data "Simultaneous start"

The simultaneous start is possible up to 4 axes.

 

 

 

List of errors/warnings

Refer to the following "Error code comparisons" and "Warning code

 

comparisons".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start history

The configuration of "start information" and "start No." is changed so that the start

 

No. can be directly checked.

 

 

 

 

 

 

 

 

 

 

 

Synchronization flag (X1)

When the PLC CPU starting method is set to asynchronous, interlock is

 

established with the synchronization flag (X1) signal.

 

 

 

 

 

 

 

Basic parameter 1 "

 

Pulse output mode"

When the PLC is turned ON or the PLC CPU module is reset, the valid value is

 

Pr.5

 

only the first value after the PLC READY signal (Y0) turns from OFF to ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A1SD75

 

QD75

 

Detailed parameters

0 (Factory

 

Software stroke limits invalid for

Software stroke limits valid for

 

setting)

 

manual operation

manual operation

 

"

 

Software stroke limit valid/invalid setting"

 

 

Pr.15

 

 

 

 

 

 

 

1

 

Software stroke limits valid for

Software stroke limits invalid for

 

 

 

 

 

 

 

manual operation

manual operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error code comparisons

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error name

 

 

 

Error code

 

 

 

 

 

 

 

A1SD75

 

 

QD75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside bias speed range

 

 

 

913

 

906

 

Illegal sudden stop deceleration time

 

 

 

962

 

961

 

Stop group 1 sudden stop selection error

 

 

 

963

 

962

 

Stop group 2 sudden stop selection error

 

 

 

964

 

963

 

Stop group 3 sudden stop selection error

 

 

 

965

 

964

 

OPR torque limit value error

 

 

 

991

 

995

 

 

 

 

 

 

 

 

Setting for the movement amount after near-point

 

992

 

991

 

dog ON error

 

 

 

 

 

 

 

 

 

 

 

 

 

OPR acceleration time selection error

 

 

 

993

 

992

 

OPR deceleration time selection error

 

 

 

994

 

993

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error type

 

 

 

Added

 

Deleted

 

Fatal error

 

 

 

002

 

51, 52

 

Common

 

 

 

 

100, 108

 

OPR, Absolute position restoration

 

 

 

213, 214

 

208

 

 

 

 

 

 

 

 

 

 

JOG/Inching operation

 

 

 

301

 

 

 

 

 

 

 

 

 

 

 

 

Manual pulse generator operation

 

 

 

 

 

 

Positioning operation

 

 

 

523, 535, 545, 546

 

509 to 512

 

I/F

 

 

 

800 to 806

 

 

 

Parameter

 

 

 

920, 935, 990, 996

 

931, 933, 938, 971, 999

 

 

 

 

 

 

 

 

 

 

Error whose name is changed: Error code 967

 

 

 

 

 

 

 

A1SD75: External start selection error

QD75: External command function selection error

Appendix - 50

Page 692
Image 692
Mitsubishi Electronics QD75P, QD75D user manual Error code comparisons