9 - 67
MELSEC-Q
9 MAJOR POSITIONING CONTROL
9.2.12 1-axis speed control
In "1-axis speed control" (" Da.2 Control system" = Forward run: speed 1, Rever se
run: speed 1), control is carried out in the ax is direction in which the positioning data
has been set by continuously outputting puls es for the speed set in " Da.8 Command
speed" until the input of a stop command.
The two types of 1-axis speed control are "F orward run: speed 1" in which the control
starts in the forward run direction, and "R everse run: speed 1" in which control starts in
the reverse run direction.
Operation chart
The following chart shows the operation timing for 1-axis speed co ntrol with axis 1
as the reference axis.
The "in speed control" flag ( Md.31 Status: b0) is turned ON during spee d control.
The "Positioning complete signal" is not turned ON.
t
V
BUSY signal OFF
ON
Positioning start signal OFF
ON
Positioning complete signal OFF
Axis stop signal
(stop command) [Y4] OFF
ON
Does not turn ON even
when control is stopped
by stop command.
OFF
ON
Md.31 Status:b0
In speed control flag
Da. 8 Command speed
[Y10]
[XC]
[X14]
Fig.9.9 1-axis speed control operation tim ing