5 DATA USED FOR POSITIONING CONTROL

[Table 1]

When " Pr.1 Unit Setting" is "mm"

MELSEC-Q

The table below lists the control systems that require the setting of the arc address and shows the setting range.

(With any control system excluded from the table below, the arc address does not need to be set.)

 

 

 

 

 

Value set with peripheral device

 

Value set with sequence program 1

 

Da.2

setting value

 

 

(m)

 

(10-1m)

 

 

 

 

 

 

ABS circular sub

: 0DH

Set the address

Set the address

ABS circular right

: 0FH

 

-214748364.8 to 214748364.7

 

-2147483648 to 2147483647

ABS circular left

: 10H

 

 

 

 

 

 

INC circular sub

: 0EH

Set the movement amount

Set the movement amount

INC circular right

: 11H

 

-214748364.8 to 214748364.7

 

-2147483648 to 2147483647

INC circular left

: 12H

 

 

 

 

 

 

1: Set an integer because the sequence program cannot handle fractions. (The value will be converted properly within the system.)

When "

Pr.1

Unit Setting" is "degree"

No control system requires the setting of the arc address by "degree".

When "

Pr.1

Unit Setting" is "pulse"

The table below lists the control systems that require the setting of the arc address and shows the setting range.

(With any control system excluded from the table below, the arc address does not need to be set.)

Da.2

setting value

Value set with peripheral device

(pulse)

Value set with sequence program 1

(pulse)

ABS circular sub

: 0DH

Set the address

Set the address

ABS circular right

: 0FH

 

-2147483648 to 2147483647

 

-2147483648 to 2147483647

ABS circular left

: 10H

 

 

 

 

 

 

INC circular sub

: 0EH

Set the movement amount

Set the movement amount

INC circular right

: 11H

 

-2147483648 to 2147483647

 

-2147483648 to 2147483647

INC circular left

: 12H

 

 

 

 

 

 

1: Set an integer because the sequence program cannot handle fractions. (The value will be converted properly within the system.)

When "

Pr.1

Unit Setting" is "inch"

The table below lists the control systems that require the setting of the arc address and shows the setting range.

(With any control system excluded from the table below, the arc address does not need to be set.)

 

 

 

 

 

Value set with peripheral device

 

Value set with sequence program 1

 

Da.2

setting value

 

 

 

 

-5

 

 

 

 

 

 

(inch)

 

(×10

inch)

 

 

 

 

 

 

ABS circular sub

: 0DH

Set the address

Set the address

 

ABS circular right

: 0FH

 

-21474.83648 to 21474.83647

 

-2147483648 to 2147483647

ABS circular left

: 10H

 

 

 

 

 

 

 

INC circular sub

: 0EH

Set the movement amount

Set the movement amount

INC circular right

: 11H

 

-21474.83648 to 21474.83647

 

-2147483648 to 2147483647

INC circular left

: 12H

 

 

 

 

 

 

 

1: Set an integer because the sequence program cannot handle fractions. (The value will be converted properly within the system.)

5 - 69

Page 157
Image 157
Mitsubishi Electronics QD75D, QD75P user manual When Pr.1 Unit Setting is mm, Da.2